Light blue top blood collection tubes are vacuum blood collection devices containing sodium citrate anticoagulant, specifically designed for coagulation testing in clinical diagnostics.
They are used to preserve whole blood in a non-clotting state by binding ionized calcium, enabling accurate measurement of clotting function parameters such as:
Unlike general laboratory tubes, light blue top tubes require strict pre-analytical control, especially in blood-to-additive ratio accuracy (typically 9:1), because even minor deviations directly affect coagulation interpretation.
Light blue top tubes are classified as high-sensitivity pre-analytical diagnostic devices, meaning that most testing errors do not originate from analyzers—but from the sample itself.
In coagulation testing, the tube is not a passive container. It actively determines the reliability of diagnostic outcomes.
If sample handling is incorrect, the following clinical misinterpretations may occur:
In critical care settings, these errors can directly influence clinical decision-making and treatment pathways, not just laboratory numbers.
The 9:1 blood-to-sodium citrate ratio is essential to maintain physiologic calcium chelation balance during testing.
Therefore, tube fill volume accuracy is not a manufacturing preference—it is a clinical validity requirement.
Even a small deviation (±10%) may shift results outside laboratory reference thresholds.
In coagulation testing, pre-analytical variability is the dominant source of diagnostic error, accounting for more than 60% of inconsistencies.
Unlike instruments, which are highly standardized, blood collection tubes introduce variability through:
These controls ensure that each tube behaves consistently in real laboratory environments, reducing inter-batch variability in diagnostic results.
According to CLSI guidelines for blood collection order, light-blue citrate tubes are positioned early in the collection sequence because they are highly susceptible to contamination and play a critical role in ensuring the accuracy of coagulation test results.
Even trace contamination from EDTA can bind calcium ions and falsely prolong coagulation times, rendering results clinically invalid.
This is why order of draw is not procedural—it is analytical contamination control logic.
The accuracy of this process depends entirely on pre-analytical control stability.
Light blue top tubes are used in high-decision-risk diagnostic scenarios, including:
These are not routine tests—they are treatment-influencing diagnostics.
Hawach light blue top tubes are designed to minimize analytical variation at the source.
The goal is not simply “blood collection”—it is preservation of diagnostic truth before analysis begins.
| Feature | Light Blue Top Tube | Serum Tube | EDTA Tube |
| Primary Function | Coagulation analysis | Chemistry testing | Hematology |
| Sample Type | Plasma | Serum | Whole blood |
| Sensitivity Level | Very high | Medium | High (cell morphology) |
| Error Risk Driver | Ratio + contamination | Hemolysis | Chelation interference |
| Clinical Impact | Direct treatment decisions | Lab reporting | Blood morphology interpretation |
Vacuum Blood Collection Tubes Overview: EDTA, heparin, citrate, fluoride, and ESR tubes from Hawach.
In coagulation diagnostics, instrument precision is not the limiting factor—sample integrity is.
Studies in clinical laboratory science consistently show that a significant proportion of coagulation testing errors originate from:
This means tube quality is directly part of the diagnostic system, not just consumable packaging.
Hawach supports global laboratory and distributor supply chains with:
Because coagulation tests directly depend on precise calcium chelation, making them highly sensitive to sample ratio and handling.
Incorrect filling can cause false PT/APTT results, potentially leading to inappropriate treatment decisions.
Because citrate provides reversible calcium binding, which is required for coagulation analysis.
To avoid contamination from EDTA or clot activators that interfere with coagulation measurements.
Yes. Even minor deviations can shift results beyond reference ranges in sensitive patients.
Need clinically reliable light blue top tubes for your laboratory? Contact Hawach for sample evaluation, technical data, and bulk pricing.
| Cat# | Description | Packaging |
| Glass, Light Blue Cap | ||
| 30011133 | PT Tube, with Sodium Citrate, 1mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011134 | PT Tube, with Sodium Citrate, 2mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011135 | PT Tube, with Sodium Citrate, 3mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011136 | PT Tube, with Sodium Citrate, 4mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011137 | PT Tube, with Sodium Citrate, 5mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011138 | PT Tube, with Sodium Citrate, 5mL, 13×100mm | 100pcs/Rack, 12Racks/Carton |
| 30011139 | PT Tube, with Sodium Citrate, 6mL, 13×100mm | 100pcs/Rack, 12Racks/Carton |
| 30011140 | PT Tube, with Sodium Citrate, 7mL, 13×100mm | 100pcs/Rack, 12Racks/Carton |
| PET, Light Blue Cap | ||
| 30011141 | PT Tube, with Sodium Citrate, 1mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011142 | PT Tube, with Sodium Citrate, 2mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011143 | PT Tube, with Sodium Citrate, 3mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011144 | PT Tube, with Sodium Citrate, 4mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011145 | PT Tube, with Sodium Citrate, 5mL, 13×75mm | 100pcs/Rack, 12Racks/Carton |
| 30011146 | PT Tube, with Sodium Citrate, 5mL, 13×100mm | 100pcs/Rack, 12Racks/Carton |
| 30011147 | PT Tube, with Sodium Citrate, 6mL, 13×100mm | 100pcs/Rack, 12Racks/Carton |
| 30011148 | PT Tube, with Sodium Citrate, 7mL, 13×100mm | 100pcs/Rack, 12Racks/Carton |

The quality has a guarantee
Fast & safe shipping worldwide