10μL – 5mL dispensing range
Up to 48 consecutive steps
Compatible with 0.5mL – 50mL tips
Lightweight & robust design
Secure tip stop lever
Availability: In Stock
10μL – 5mL dispensing range
Up to 48 consecutive steps
Compatible with 0.5mL – 50mL tips
Lightweight & robust design
Secure tip stop lever
Availability: In Stock
The Hawach Repeater Pipette is a manual positive displacement pipette designed for repetitive dispensing of liquids from 10 μL to 5 mL. By aspirating liquid once and dispensing multiple equal aliquots without refilling, it significantly improves workflow efficiency and reduces operator fatigue during repetitive laboratory procedures.
Compatible with disposable dispenser tips ranging from 0.5 mL to 50 mL, the pipette supports up to 48 dispensing cycles from a single aspiration. It is suitable for aqueous, viscous, volatile, and foaming liquids, making it ideal for clinical diagnostics, molecular biology, pharmaceutical research, chemical analysis, food testing, and industrial quality control laboratories.
Its lightweight ergonomic design, secure tip locking mechanism, and reliable positive displacement principle ensure accurate and reproducible dispensing performance even when handling challenging liquid types.
Designed for comfortable, fatigue-free operation during extended repetitive dispensing sessions. The lightweight body reduces hand strain while maintaining durability for daily laboratory use.
Covers a broad volume range from 10μL to 5mL, accommodating diverse experimental needs from micro-volume assays to larger reagent transfers.
Single aspiration enables up to 48 consecutive dispensing steps without refilling, streamlining lengthy workflows and improving efficiency.
Equipped with a durable dispenser tip stop lever that securely locks disposable polypropylene dispenser tips in place, preventing accidental detachment during use.
Compatible with a variety of disposable polypropylene dispenser tips ranging from 0.5mL to 50mL, providing flexibility across different volume requirements.
Based on the positive displacement principle, this repeater pipette ensures accurate dispensing regardless of liquid density, viscosity, or volatility – ideal for challenging liquids.
Serial dispensing of diagnostic reagents, sample aliquoting, and high-throughput testing.
Filling microplates, nucleic acid purification kits, and cell culture media preparation.
Reagent dispensing for analytical chemistry, quality control, and formulation development.
Repetitive addition of standards, buffers, and additives in quality testing workflows.
Serial dispensing for drug formulation, dissolution testing, and stability studies.
| Feature | Repeater Pipette | Standard Micropipette |
| Repeated Dispensing | Excellent | Limited |
| High-Throughput Workflows | Excellent | Moderate |
| Operator Fatigue | Low | Higher |
| Viscous Liquids | Excellent | Limited |
| Volatile Liquids | Excellent | Limited |
| Reagent Aliquoting | Ideal | Acceptable |
For laboratories performing repetitive liquid dispensing, a repeater pipette offers higher efficiency, improved consistency, and reduced hand strain compared with conventional air displacement micropipettes.
| Tip Volume | Setting 1 | Setting 2 | Setting 3 | Setting 4 | Setting 5 |
| 0.5 mL | 10 μL | 20 μL | 30 μL | 40 μL | 50 μL |
| 1.25 mL | 25 μL | 50 μL | 75 μL | 100 μL | 125 μL |
| 2.50 mL | 50 μL | 100 μL | 150 μL | 200 μL | 250 μL |
| 5.00 mL | 100 μL | 200 μL | 300 μL | 400 μL | 500 μL |
| 12.50 mL | 250 μL | 500 μL | 750 μL | 1000 μL | 1250 μL |
| 25.00 mL | 500 μL | 1000 μL | 1500 μL | 2000 μL | 2500 μL |
| 50.00 mL | 1000 μL | 2000 μL | 3000 μL | 4000 μL | 5000 μL |
| Steps | 48 | 23 | 15 | 11 | 8 |
Note: The number of dispensing steps indicates how many aliquots can be dispensed from a single tip fill at the corresponding setting.
The Hawach Repeater Pipette is designed for use with disposable positive displacement dispenser tips. Multiple tip capacities are available to cover a wide range of repetitive dispensing applications.
| Dispenser Tip Capacity | Typical Dispensing Range |
| 0.5 mL | 10-50 μL |
| 1.25 mL | 25-125 μL |
| 2.5 mL | 50-250 μL |
| 5 mL | 100-500 μL |
| 12.5 mL | 250-1250 μL |
| 25 mL | 500-2500 μL |
| 50 mL | 1000-5000 μL |
The Hawach Repeater Pipette is factory calibrated to provide reliable dispensing accuracy and reproducibility across the entire operating range.
| Performance Parameter | Specification |
| Accuracy (A%) | ±0.8% |
| Precision (CV%) | ≤0.7% |
| Calibration | Factory calibrated before shipment |
| Operating Principle | Positive displacement dispensing |
| Dispensing Volume Range | 10 μL – 5 mL (depending on tip and dial setting) |
| Maximum Dispensing Steps | Up to 48 steps per single aspiration |
| Compatible Tips | Disposable polypropylene dispenser tips: 0.5 mL, 1.25 mL, 2.5 mL, 5 mL, 12.5 mL, 25 mL, 50 mL |
| Tip Stop Mechanism | Durable dispenser tip stop lever for secure locking |
| Operating Principle | Positive displacement / forward pipetting principle |
| Design | Slim, lightweight, robust |
| Applications | Clinical, biological, chemical, food & beverage, pharmaceutical laboratories |
Aspirate once and dispense up to 48 times – significantly reducing handling time and improving workflow efficiency.
Lightweight design and smooth operation minimize hand fatigue during long dispensing series, protecting operator health.
By reducing the number of fill/dispense sequences, the repeater pipette lowers the risk of volume errors and improves consistency across samples.
When multichannel pipettes are outside of budget, repeater pipettes offer a cost-effective method to increase repetitive dispensing efficiency.
Suitable for a wide range of liquids – including viscous, volatile, and foaming samples – when used with appropriate dispenser tips.
One disposable tip can be used for many dispensing steps, reducing plastic waste compared to changing tips for each individual transfer.
ISO 9001 Factory Factory Calibrated CE Compliant OEM Available
A repeater pipette is used to dispense the same liquid volume multiple times from a single aspiration. It is commonly used for microplate filling, reagent aliquoting, serial dispensing, and high-throughput laboratory workflows.
A standard micropipette requires a new aspiration before every dispense. A repeater pipette allows multiple dispensing cycles after one aspiration, significantly increasing efficiency for repetitive liquid handling tasks.
Yes. The positive displacement operating principle enables accurate dispensing of viscous, volatile, foaming, and high-density liquids when used with compatible dispenser tips.
Depending on the selected dial setting and dispenser tip size, up to 48 dispensing cycles can be performed from a single aspiration.
Compatible dispenser tips are available in capacities of 0.5 mL, 1.25 mL, 2.5 mL, 5 mL, 12.5 mL, 25 mL, and 50 mL.
| Model | Description |
| 21041001 | Repeater Pipette, 10 μL-5 mL, Manual Positive Displacement Type |
Download PDF Datasheet
OEM & Private Label Available

The quality has a guarantee
Fast & safe shipping worldwide