+86-29-89284429

PTFE Membrane Filter | 0.1-5.0 μm

Organic Solvent Filtration | HPLC Mobile Phase | Gas Venting

Drop-in Replacement: Millipore, Whatman, Advantec
Also available: Custom rolls & OEM supply

Availability: In Stock

Description

Why Labs & Procurement Choose Hawach

  • Industry-Standard Membrane: HPLC / LC-MS mobile phase filtration, gas venting, aggressive organic solvents.
  • Inherently Hydrophobic: No surfactant coating → zero contamination risk.
  • Low Extractable: Protects sensitive analytical baselines, reduces ghost peaks.
  • Extreme Chemical Resistance: Stable pH 1–14, compatible with strong acids, bases, and solvents.
  • High Flow & Sterilization Compatible: Optimized pore network, autoclave & gamma irradiation safe.
  • Procurement Advantages: Direct replacement for Millipore, Whatman, Advantec; OEM & bulk options available; batch-to-batch pore consistency.

Recognized as direct replacement for top lab brands in analytical and industrial solvent filtration.

What is PTFE Membrane?

Polytetrafluoroethylene (PTFE) membrane is a premium fluoropolymer filtration material with:

  • Inherent chemical inertness – resists most lab solvents, strong acids & bases
  • Natural hydrophobicity – water repellent, no surfactant coating
  • Thermal stability – continuous use up to 130°C, fully autoclavable
  • Low extractable composition – ideal for HPLC, LC-MS, trace analysis

Two categories: Hydrophobic (organic solvents & gas) and Hydrophilic (aqueous & biological samples). Hawach hydrophobic PTFE retains the native non-wettable structure, eliminating coating-related contamination risks.

Selection Algorithm – Which Membrane Fits Your Workflow?

Workflow InvolvesRecommended MembraneReason
Organic solvents (ACN, MeOH, THF, hexane)Hydrophobic PTFEIndustry standard for non-aqueous filtration
Aqueous buffers & biological samplesHydrophilic PTFE / PES / NylonNatural water penetration
HPLC / LC-MS mobile phase prep0.22 μm Low Extractable PTFEMinimizes ghost peaks & protects columns
Gas venting & sterile air filtration0.22–0.45 μm Hydrophobic PTFEHigh airflow with liquid barrier
Aggressive strong acid / base filtrationHydrophobic PTFEMaximum chemical inertness

10-Second Pore Size Guide

ApplicationRecommended Pore SizeBenefit
HPLC mobile phase filtration0.22 μmFine particle removal, column protection
General organic solvent filtration0.45 μmBalanced flow & retention
Gas venting / sterile air0.22–0.45 μmHigh airflow, reliable liquid barrier
Viscous solvents / prefiltration1.0–5.0 μmHigh throughput & less clogging

Hydrophobic vs Hydrophilic PTFE

PropertyHydrophobic PTFEHydrophilic PTFE
Water filtrationNot suitableCompatible
Organic solvent performanceExcellentLimited
Gas ventingIdealNot preferred
HPLC mobile phaseStandard choiceLimited application
Pre-wetting requiredNoUsually required

Why PTFE Over Nylon, PES, PVDF?

MembraneSolvent ResistanceNatural HydrophobicBest Use Case
PTFEExcellentYesOrganic solvents, HPLC, gas venting
NylonModerateNoGeneral aqueous filtration
PESLimitedNoBiological aqueous samples
PVDFGoodOptionalProtein & biomolecular applications

Core Technical Specifications

ParameterSpecification
MaterialNatural hydrophobic PTFE
Pore Sizes0.1 / 0.22 / 0.45 / 5.0 μm
Diameter Range13 / 25 / 47 / 50 / 60 / 90 / 142 mm
WettabilityNon-wettable / hydrophobic
ExtractablesLow – HPLC & LC-MS grade
pH Compatibility1–14
Max Continuous Temp130°C
SterilizationAutoclavable, Gamma irradiation compatible

Scanning Electron Microscope Picture

hydrophobic-ptfe-membrane-filter

Ordering Information – Full SKU List

0.1 μm pore size

SKUDiameterPack Quantity
1114710113 mm400 pcs/pk
1114710325 mm200 pcs/pk
1114710447 mm100 pcs/pk
1114710550 mm100 pcs/pk
1114710660 mm50 pcs/pk
1114710790 mm50 pcs/pk
11147110142 mm50 pcs/pk

0.22 μm pore size

SKUDiameterPack Quantity
1114711413 mm400 pcs/pk
1114711625 mm200 pcs/pk
1114711747 mm100 pcs/pk
1114711850 mm100 pcs/pk
1114711960 mm50 pcs/pk
1114712090 mm50 pcs/pk
11147123142 mm50 pcs/pk

0.45 μm pore size

SKUDiameterPack Quantity
1114712713 mm400 pcs/pk
1114712925 mm200 pcs/pk
1114713047 mm100 pcs/pk
1114713150 mm100 pcs/pk
1114713260 mm50 pcs/pk
1114713390 mm50 pcs/pk
11147136142 mm50 pcs/pk

5.0 μm pore size

SKUDiameterPack Quantity
1114714013 mm400 pcs/pk
1114714225 mm200 pcs/pk
1114714347 mm100 pcs/pk
1114714450 mm100 pcs/pk
1114714560 mm50 pcs/pk
1114714690 mm50 pcs/pk
11147149142 mm50 pcs/pk

Download PDF Datasheet
Membrane rolls (bulk sheets) also available – Contact sales@hawach.com with width, length, and pore size.

Typical Applications

  • HPLC & UHPLC: Mobile phase filtration, particulate removal, column protection
  • Pharmaceutical Manufacturing: API synthesis, reaction mixture filtration, solvent purification
  • Gas & Air Systems: Sterile venting, fermentation airflow control, environmental monitoring
  • Chemical Industry: Strong acid/base clarification, organic synthesis solution filtration

Chemical Compatibility

Compatible: Acetonitrile, methanol, ethanol, acetone, THF, hexane, toluene, DMF, DCM, hydrocarbon oils, dilute strong acids & bases.

Not Recommended: Pure aqueous filtration (use hydrophilic PTFE), fuming strong oxidants at high temperature.

Manufacturing & Quality System

  • ISO-controlled cleanroom production
  • Per-batch bubble point & pore consistency validation
  • Full lot traceability + COA documentation
  • Stable global supply chain
  • OEM private label & custom conversion available

FAQ

Can hydrophobic PTFE filter water?

Use hydrophilic PTFE for aqueous samples.

What solvents is it compatible with?

Most organic solvents including ACN, MeOH, THF, hexane, acetone, chlorinated solvents.

Is it suitable for HPLC mobile phase filtration?

Low extractable grade ensures stable baseline and minimal analytical interference.

Standard pore size for HPLC?

22 μm.

OEM / custom sizes available?

Yes – custom diameters, pore sizes, membrane rolls, private label packaging.

Free lab samples?

Yes – 13/25/47 mm discs for qualified labs.

Request Free Samples & Bulk Quotation

Free membrane samples (13/25/47 mm, any pore size) for lab evaluation. Bulk pricing, OEM customization, COA & batch reports available. Membrane rolls & custom dimensions available on request.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top