+86-29-89284429

PES Syringe Filters

Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.1μm, 0.22μm, 0.45μm, 0.65μm, 1.0μm
Inlet: Female Luer lock (50mm Diameter Stepped barb)
Outlet: Male Luer Slip (50mm Diameter Stepped barb)
Housing: Medical PP
Pre-filter: 1μm GF or PP
Maximum Pressure: 5.2bar
Operate Temperature: 60°C

Availability: In Stock

Description

High-Performance Hydrophilic Filtration for Aqueous & Biological Applications

Hawach PES syringe filters are engineered for high-efficiency aqueous filtration and biological sample processing. Featuring a premium hydrophilic polyethersulfone (PES) membrane, they deliver:

  • Ultra-low protein binding
  • Fast filtration speed
  • High sample recovery
  • Excellent reproducibility

They are widely used in HPLC sample preparation, cell culture media sterilization, pharmaceutical QC, and biological research.

Recommended Choice for Most Laboratories

Hawach Standard PES Syringe Filters (0.22 µm / 0.45 µm)

  • No pre-wetting required (hydrophilic membrane)
  • Ultra-low protein adsorption for biological samples
  • Fast flow rate reduces filtration time
  • Compatible with buffers, aqueous reagents, and media
  • Available in sterile and non-sterile formats

Ideal for HPLC sample filtration and routine lab use

Related product: PTFE Syringe Filters for Organic Solvents

Instruction Drawing

syringe-filters-analysis-chart-800x281 (2)

Quick Selection Guide

ApplicationRecommended SeriesPore Size
HPLC / UHPLC sample prepStandard PES0.22 µm
Cell culture media sterilizationSterile PES0.22 µm
Buffer / aqueous clarificationStandard PES0.45 µm
Protein / enzyme filtrationSterile PES0.22 µm
Pre-filtration (dirty samples)Disposable PES0.65–1.0 µm

Product Series Overview

1. Disposable PES Syringe Filters (Routine Use)

Designed for cost-effective, single-use laboratory filtration

  • Non-sterile format
  • Fast filtration performance
  • Ideal for pre-filtration and buffer work
  • Minimizes cross-contamination risk

Related: Nylon Syringe Filters for General Filtration

2. Standard PES Syringe Filters (Analytical Grade)

Designed for HPLC / GC and aqueous analysis workflows

  • Low protein binding
  • Stable pore structure
  • High reproducibility
  • Optional sterile versions

Related: PVDF Syringe Filters for Protein & Biological Samples

3. Sterile PES Syringe Filters (Biotech Grade)

Designed for cell culture and pharmaceutical sterile filtration

  • Gamma irradiated (SAL 10⁻⁶)
  • Endotoxin controlled
  • Ready-to-use sterile packaging
  • Ideal for sensitive biological workflows

Applications

PES syringe filters are widely used in:

  • HPLC / UHPLC / GC sample preparation
  • Cell culture media sterilization
  • Protein & enzyme filtration
  • Buffer and aqueous solution clarification
  • Pharmaceutical quality control (QC)
  • Environmental water testing
  • Microbiological analysis

Why PES Membrane?

Polyethersulfone (PES) is one of the most advanced filtration membranes for aqueous systems.

Key advantages:

  • Hydrophilic surface → no pre-wetting required
  • Ultra-low protein binding → protects sample integrity
  • High permeability → faster workflow
  • Stable pore structure → reproducible results
  • Broad aqueous compatibility

Compared with other membranes:

MembraneBest UseLimitation
PESAqueous & biological samplesNot for organic solvents
PTFEOrganic solvents & gasesRequires pre-wetting
PVDFProtein workModerate binding
NylonGeneral filtrationHigher adsorption

Technical Specifications

ParameterSpecification
MembranePolyethersulfone (PES), hydrophilic
Pore Sizes0.1 / 0.22 / 0.45 / 0.65 / 1.0 µm
Diameters4 / 13 / 25 / 33 / 50 mm
HousingMedical-grade polypropylene (PP)
Max Pressure5.2–6.2 bar
TemperatureUp to 60°C
Protein BindingUltra-low
SterilityGamma irradiated (sterile series)

SKU Table

Disposable PES Syringe Filters

Item CodePore Size(μm)Diameter(mm)SterileQuantity/pk
110422010.2213No100pcs
110422020.4513
110422030.2225
110422040.4525

Standard PES Syringe Filters

The following product codes help users quickly identify the correct configuration based on pore size, diameter, and sterility requirements.

Cat#Pore Size(μm)Diameter(mm)SterilePre-filterPackage(pcs/pk)
110442010.14NoNo100
110442020.224NoNo100
110442030.454NoNo100
110482070.113NoNo100
110432010.2213NoNo100
110432020.4513NoNo100
110482130.125NoNo100
110432030.2225NoNo100
110432040.4525NoNo100
110482190.133NoNo50
110482200.2233NoNo50
110482210.4533NoNo50
110482270.150NoNo25
110482280.2250NoNo25
110482290.4550NoNo25
110486010.113NoPP100
110486020.2213NoPP100
110486030.4513NoPP100
110486090.125NoPP100
110486100.2225NoPP100
110486110.4525NoPP100
110486170.133NoPP50
110486180.2233NoPP50
110486190.4533NoPP50
110486330.113NoGF100
110486340.2213NoGF100
110486350.4513NoGF100
110486410.125NoGF100
110486420.2225NoGF100
110486430.4525NoGF100
110486490.133NoGF50
110486500.2233NoGF50
110486510.4533NoGF50

Sterile PES Syringe Filters

The following product codes help users quickly identify the correct configuration based on pore size, diameter, and sterility requirements.

Cat#Pore Size(μm)Diameter(mm)SterilePackage(pcs/pk)
110444010.14Gamma sterile100
110444020.224Gamma sterile100
110444030.454Gamma sterile100
110444040.654Gamma sterile100
110444050.84Gamma sterile100
1104440614Gamma sterile100
1104440734Gamma sterile100
1104440854Gamma sterile100
110484070.113Gamma sterile100
110484030.2213Gamma sterile100
110484040.4513Gamma sterile100
110484080.6513Gamma sterile100
110484090.813Gamma sterile100
110484101.213Gamma sterile100
11048411313Gamma sterile100
11048412513Gamma sterile100
110484130.125Gamma sterile100
110484050.2225Gamma sterile100
110484060.4525Gamma sterile100
110484140.6525Gamma sterile100
110484150.825Gamma sterile100
110484161.225Gamma sterile100
11048417325Gamma sterile100
11048418525Gamma sterile100
110484190.133Gamma sterile50
110484200.2233Gamma sterile50
110484210.4533Gamma sterile50
110484220.6533Gamma sterile50
110484230.833Gamma sterile50
110484241.233Gamma sterile50
11048425333Gamma sterile50
11048426533Gamma sterile50
110484270.150Gamma sterile25
110484280.2250Gamma sterile25
110484290.4550Gamma sterile25
110484300.6550Gamma sterile25
110484310.850Gamma sterile25
110484321.250Gamma sterile25
11048433350Gamma sterile25
11048434550Gamma sterile25

Why Choose Hawach PES Syringe Filters?

  • Stable batch-to-batch quality
  • ISO 9001 / ISO 13485 certified production
  • ISO Class 7 cleanroom manufacturing
  • Gamma sterilization (SAL 10⁻⁶)
  • Endotoxin tested (<0.25 EU/mL)
  • OEM / private label available
  • Global bulk supply capability

Bulk Order & OEM Supply

We support global laboratory and distributor supply chains.

  • Factory direct pricing
  • OEM branding / packaging
  • Bulk order discounts
  • Fast global shipping
  • Technical support for applications

Get quote in 24 hours

FAQ

What is a PES syringe filter used for?

PES syringe filters are used for aqueous and biological sample filtration, including HPLC, cell culture media, and pharmaceutical applications.

What is the difference between PES and PTFE syringe filters?

PES is hydrophilic and ideal for water-based solutions, while PTFE is hydrophobic and used for organic solvents and gases.

Related: PTFE Syringe Filters Guide

Are PES syringe filters suitable for sterile filtration?

Yes, sterile PES syringe filters are widely used for cell culture and biological sterilization applications.

Do PES filters bind proteins?

No. PES has ultra-low protein binding, making it ideal for sensitive biological samples.

What pore size should I choose?

  • 0.22 µm → Sterile filtration
  • 0.45 µm → General clarification
  • 1.0 µm → Pre-filtration

Are these filters reusable?

No. Syringe filters are designed for single-use to prevent contamination.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top