Sample Vials for HPLC, GC & LC-MS
Autosampler Vials & Closures
Complete range of 2 mL crimp, screw, snap top vials, headspace vials (10/20 mL), storage vials (20/40 mL) and inserts. Direct OEM replacements for Agilent, Waters, Shimadzu, Thermo. Bulk supply, private label, 24h RFQ.
Common Issues with Chromatography Vials
We provide validated vial alternatives. Send your current brand → solution in 24h.
Procurement Decision – Which Vial Type?
| Application Need | Recommended Vial Type | Key Feature | Risk if Wrong |
|---|---|---|---|
| Volatile samples / GC-MS / long storage | Crimp top | Permanent aluminum seal | Sample evaporation, low sensitivity |
| Routine HPLC, reusable workflows | Screw top (9-425) | Reusable vial, easy capping | Higher evaporation risk |
| High-throughput, manual operation | Snap top | Tool‑free, audible click | Seal integrity lower for volatiles |
| Headspace GC (VOC analysis) | Headspace vials, 10/20 mL | Thicker wall, pressure resistant | Vial cracking, analyte loss |
| Long‑term sample storage | Storage vials, 20/40 mL | USP Type I glass, PTFE liner | Sample degradation, pH shift |
| Low volume samples (<200 µL) | Vial inserts | Conical/pulled‑point, spring options | Incomplete injection, wasted sample |
Pharma & environmental labs
Dimensional & vapor loss data
Certified quality system
Confirm compatibility before order
Request evaluation units
Complete Sample Vial Product Line
All vials manufactured from USP Type I borosilicate glass, dimensionally tested for autosampler compatibility. Direct replacements for Agilent, Waters, Shimadzu, Thermo, PerkinElmer.
| Vial Type | Volume | Neck/Thread | Key Feature | Common Brand Equivalent | Action |
|---|---|---|---|---|---|
| Crimp Top | 2 mL | 11 mm | Permanent seal, best for volatiles | Agilent 5182-0714, Waters 186000307 | View |
| Screw Top | 2 mL | 9-425 thread | Reusable, color caps, easy | 8-425 / 9-425 universal | View |
| Snap Top | 2 mL | 11 mm snap ring | Tool‑free, audible click | 11 mm snap cap standard | View |
| Headspace Vials | 10/20 mL | 20 mm crimp or screw | Thicker wall, high pressure | Agilent, Thermo, PerkinElmer | View |
| Storage Vials (EPA VOA) | 20/40 mL | 24 mm screw | USP Type I, PTFE liner | EPA VOA spec | View |
| HPLC Vial Inserts | 150/250/300 µL | 5-6 mm OD | Conical/flat/spring, max recovery | Standard 8 mm opening | View |
Direct Replacement Guide – Cross Reference
Compatible with major autosampler brands. Switch without adjusting your instrument or method.
| If you are using | Hawach Equivalent | Key Advantage |
|---|---|---|
| Agilent 2 mL crimp (5182-0714) | Hawach Crimp Top | Same 12×32 mm, same seal integrity |
| Waters screw top vials | Hawach Screw Top | 9-425 thread, blue caps available |
| Thermo headspace vials | Hawach Headspace | 20 mm crimp, flat/round bottom |
| EPA 40 mL VOA vials | Hawach Storage Vials | PTFE/silicone liner, certified option |
How to Select the Right Vial & Closure
| Need / Application | Recommended Vial | Cap/Septa Recommendation |
|---|---|---|
| Volatile organics, GC-MS | Crimp top, 2 mL | Aluminum seal + PTFE/silicone septum |
| Routine HPLC, reusable | Screw top, 2 mL | Blue polypropylene cap, bonded septa |
| Headspace GC (VOCs) | 20 mL headspace vial | Aluminum crimp cap with PTFE/silicone septa |
| Limited sample volume (<200 µL) | 2 mL vial + insert | Conical or pulled‑point insert (with spring) |
| Long-term storage | 20/40 mL storage vial | Screw cap with PTFE/silicone liner |
Typical Applications by Industry
Assay, purity, residual solvents, stability
VOCs, SVOCs, water/wastewater (EPA methods)
Flavor, fragrance, pesticide residue
Blood alcohol, toxicology, therapeutic drug monitoring
Hydrocarbon analysis, fuel testing
Available Configurations & OEM Services
Clear / amber glass, white / brown, with/without writing patch
Solid caps, pre‑slit, bonded, magnetic for headspace
Laser‑etched logo, private label box, blister packs, bulk cartons
Custom vial dimensions and insert configurations available for OEM partners.
Quality Control & Compliance – Factory Direct
USP Type I borosilicate glass
Dimensional inspection (12×32 mm ±0.1)
Vapor loss and septa integrity test
Batch traceability & COA available
1‑Minute Summary – Your Path to Better Vial Supply
Crimp/screw/snap/headspace/storage/insert
We match catalog numbers
Free sample evaluation, datasheet
Frequently Asked Questions – Sample Vials
What is the difference between crimp, screw and snap top vials?
Crimp vials provide the best seal for volatile samples but require a crimping tool. Screw vials are reusable and convenient for routine HPLC. Snap vials offer tool‑free sealing with an audible click but lower evaporation resistance.
Which vial is best for headspace GC?
Use 20 mL headspace vials (crimp top) with PTFE/silicone septa. They have thicker walls to withstand internal pressure.
What insert should I use for very small sample volumes?
For 2 mL vials, use a 150 µL conical or pulled‑point insert. For viscous samples, add a spring (polyspring) to push the insert upward.
Can I get samples before placing a bulk order?
Absolutely. Request evaluation samples of any vial type – we ship free samples for qualified labs.
Send Your Current Vial Catalog Number – Get Validated Equivalent + Quote in 24h
Stop overpaying or risking instrument downtime. Tell us the brand and part number you are using → we will reply with a matching equivalent, full datasheet, and a competitive bulk or OEM price.