+86-29-89284429

Sample Vials for HPLC, GC & LC-MS
Autosampler Vials & Closures

Complete range of 2 mL crimp, screw, snap top vials, headspace vials (10/20 mL), storage vials (20/40 mL) and inserts. Direct OEM replacements for Agilent, Waters, Shimadzu, Thermo. Bulk supply, private label, 24h RFQ.

6+ Vial Types
OEM Private Label
24h RFQ
USP Type I Glass
Factory Direct

Common Issues with Chromatography Vials

Evaporation leads to concentration change → Need proper seal (crimp or high‑quality screw)
Sample carryover and contamination → Low‑extractable glass & clean septa
Needle damage from bottoming out → Use inserts or conica vials
Inconsistent headspace results → Precision‑manufactured headspace vials

We provide validated vial alternatives. Send your current brand → solution in 24h.

Procurement Decision – Which Vial Type?

Application NeedRecommended Vial TypeKey FeatureRisk if Wrong
Volatile samples / GC-MS / long storageCrimp topPermanent aluminum sealSample evaporation, low sensitivity
Routine HPLC, reusable workflowsScrew top (9-425)Reusable vial, easy cappingHigher evaporation risk
High-throughput, manual operationSnap topTool‑free, audible clickSeal integrity lower for volatiles
Headspace GC (VOC analysis)Headspace vials, 10/20 mLThicker wall, pressure resistantVial cracking, analyte loss
Long‑term sample storageStorage vials, 20/40 mLUSP Type I glass, PTFE linerSample degradation, pH shift
Low volume samples (<200 µL)Vial insertsConical/pulled‑point, spring optionsIncomplete injection, wasted sample

Export to 60+ countries
Pharma & environmental labs
Batch test report
Dimensional & vapor loss data
ISO 9001:2024
Certified quality system
Free validation
Confirm compatibility before order
Sample available
Request evaluation units

Complete Sample Vial Product Line

All vials manufactured from USP Type I borosilicate glass, dimensionally tested for autosampler compatibility. Direct replacements for Agilent, Waters, Shimadzu, Thermo, PerkinElmer.

Vial TypeVolumeNeck/ThreadKey FeatureCommon Brand EquivalentAction
Crimp Top2 mL11 mmPermanent seal, best for volatilesAgilent 5182-0714, Waters 186000307View
Screw Top2 mL9-425 threadReusable, color caps, easy8-425 / 9-425 universalView
Snap Top2 mL11 mm snap ringTool‑free, audible click11 mm snap cap standardView
Headspace Vials10/20 mL20 mm crimp or screwThicker wall, high pressureAgilent, Thermo, PerkinElmerView
Storage Vials (EPA VOA)20/40 mL24 mm screwUSP Type I, PTFE linerEPA VOA specView
HPLC Vial Inserts150/250/300 µL5-6 mm ODConical/flat/spring, max recoveryStandard 8 mm openingView

Direct Replacement Guide – Cross Reference

Compatible with major autosampler brands. Switch without adjusting your instrument or method.

If you are usingHawach EquivalentKey Advantage
Agilent 2 mL crimp (5182-0714)Hawach Crimp TopSame 12×32 mm, same seal integrity
Waters screw top vialsHawach Screw Top9-425 thread, blue caps available
Thermo headspace vialsHawach Headspace20 mm crimp, flat/round bottom
EPA 40 mL VOA vialsHawach Storage VialsPTFE/silicone liner, certified option

How to Select the Right Vial & Closure

Need / ApplicationRecommended VialCap/Septa Recommendation
Volatile organics, GC-MSCrimp top, 2 mLAluminum seal + PTFE/silicone septum
Routine HPLC, reusableScrew top, 2 mLBlue polypropylene cap, bonded septa
Headspace GC (VOCs)20 mL headspace vialAluminum crimp cap with PTFE/silicone septa
Limited sample volume (<200 µL)2 mL vial + insertConical or pulled‑point insert (with spring)
Long-term storage20/40 mL storage vialScrew cap with PTFE/silicone liner

Typical Applications by Industry

Pharmaceutical QC
Assay, purity, residual solvents, stability
Environmental Testing
VOCs, SVOCs, water/wastewater (EPA methods)
Food & Beverage
Flavor, fragrance, pesticide residue
Clinical & Forensic
Blood alcohol, toxicology, therapeutic drug monitoring
Petrochemical
Hydrocarbon analysis, fuel testing

Available Configurations & OEM Services

Vial Options
Clear / amber glass, white / brown, with/without writing patch
Caps & Septa
Solid caps, pre‑slit, bonded, magnetic for headspace
OEM Customization
Laser‑etched logo, private label box, blister packs, bulk cartons

Custom vial dimensions and insert configurations available for OEM partners.

Quality Control & Compliance – Factory Direct

USP Type I borosilicate glass

Dimensional inspection (12×32 mm ±0.1)

Vapor loss and septa integrity test

Batch traceability & COA available

1‑Minute Summary – Your Path to Better Vial Supply

1. Choose vial type
Crimp/screw/snap/headspace/storage/insert
2. Send your current brand
We match catalog numbers
3. Get equivalent + quote in 24h
Free sample evaluation, datasheet

Start Now – Send Your Current Vial

Frequently Asked Questions – Sample Vials

What is the difference between crimp, screw and snap top vials?

Crimp vials provide the best seal for volatile samples but require a crimping tool. Screw vials are reusable and convenient for routine HPLC. Snap vials offer tool‑free sealing with an audible click but lower evaporation resistance.

Which vial is best for headspace GC?

Use 20 mL headspace vials (crimp top) with PTFE/silicone septa. They have thicker walls to withstand internal pressure.

What insert should I use for very small sample volumes?

For 2 mL vials, use a 150 µL conical or pulled‑point insert. For viscous samples, add a spring (polyspring) to push the insert upward.

Can I get samples before placing a bulk order?

Absolutely. Request evaluation samples of any vial type – we ship free samples for qualified labs.

Send Your Current Vial Catalog Number – Get Validated Equivalent + Quote in 24h

Stop overpaying or risking instrument downtime. Tell us the brand and part number you are using → we will reply with a matching equivalent, full datasheet, and a competitive bulk or OEM price.

24h Response
Free Cross‑Reference Report
Sample Available
Flexible MOQ

Industrial Procurement Quick Form

    Go to Top