+86-29-89284429

Laboratory Water Distiller

Output: 3 – 20 L/H
Material: Stainless steel
Power: 2.5KW / 4.5KW / 7.5KW / 13.5KW
Voltage: 110V / 220V / 380V
Cut-off protection (select models)

Availability: In Stock

Description

Designed for laboratories, medical facilities, pharmaceutical preparation, and industrial applications requiring high-purity distilled water. Produces pyrogen-free, mineral-free water by boiling, vaporization, and condensation. Suitable for analytical chemistry, microbiology media preparation, clinical analyzers, and instrument rinsing.

Application Areas – Laboratory & Industrial Use

Laboratory Water Distiller for Analytical Chemistry

Provides high-purity distilled water for preparing reagents, standard solutions, and dilutions. Ideal for HPLC, atomic absorption, and general wet chemistry.

Medical & Pharmaceutical Distilled Water Generator

Used for cleaning medical instruments, autoclave feed water, preparing medicinal liquids, and in vitro diagnostic reagent preparation. Complies with clinical lab water standards.

Industrial & Manufacturing Distillation System

Serves as a cleaning agent or solvent for industrial processes, battery top-up, and cooling system make-up water.

Research & Education Laboratory Water Still

Essential for university teaching labs, research institutes, and microbiology labs requiring consistent, contaminant-free water.

How to Choose the Right Laboratory Water Distiller

3-5 L/H – Small Lab / Bench Top

Best for: Low daily consumption (e.g., reagent prep, glassware rinsing).

Models: 18251001-18251004

Output: 3L/H or 5L/H

Voltage: 110V/220V, power 2.5KW / 4.5KW

Compact size, fits on bench.

10 L/H – Medium Lab / Clinical

Best for: Clinical analyzers, microbiology media preparation, autoclave feed.

Models: 18251005 / 18251006

Output: 10L/H, 380V, 7.5KW

Water cut-off protection available.

20 L/H – High-Volume / Industrial

Best for: Pharmaceutical production, large-scale cleaning, continuous process water.

Models: 18251007 / 18251008

Output: 20L/H, 380V, 13.5KW

Heavy-duty stainless steel construction.

Standard vs Water Cut-off Protection models: Models ending with even numbers (18251002, 18251004, 18251006, 18251008) include an automatic cut-off safety feature that stops heating when water supply fails or the tank is empty – preventing dry burning and extending heater life. Recommended for unattended operation.

Specification Comparison

Cat. No.OutputVoltagePowerCut-off ProtectionDimensions (H×Diam.)Gross Weight
182510013 L/H110V/220V2.5KWNo71×31 cm4 kg
182510023 L/H110V/220V2.5KWYes71×31 cm4 kg
182510035 L/H110V/220V4.5KWNo71×31 cm4 kg
182510045 L/H110V/220V4.5KWYes71×31 cm4 kg
1825100510 L/H380V7.5KWNo77×35 cm6 kg
1825100610 L/H380V7.5KWYes77×35 cm6 kg
1825100720 L/H380V13.5KWNo73×45 cm8.5 kg
1825100820 L/H380V13.5KWYes73×45 cm8.5 kg

Why Laboratories Choose Hawach Water Distiller

  • High-grade stainless steel construction– evaporator, condenser, and coils made from premium imported stainless steel, rolled, stretched, and precision welded.
  • Anti-splash steam blocking cap– prevents water droplets from being carried over into distillate, ensuring purity.
  • Easy scale removal– evaporator can be cleaned with acid or alkali solutions; drain cock allows convenient flushing.
  • Efficient condensing system– stainless steel coils provide high heat exchange rate and are removable for internal cleaning.
  • Durable heating element– T4 copper-sheathed, tin-plated electric heating tube for long service life.
  • Automatic water cut-off protection(select models) – prevents dry heating, enhances safety.
  • Wide voltage compatibility– 110V, 220V, and 380V models available to suit global lab power standards.

Compliance & Quality Standards

Hawach Laboratory Water Distillers are manufactured under ISO 9001 quality management. The water produced meets CLSI (Clinical and Laboratory Standards Institute) Type III water specifications and is suitable for use in GLP, GMP, and ISO 17025 accredited labs. Optional water cut-off protection complies with basic electrical safety requirements.

Product Construction & Features

  • Evaporator: High-quality stainless steel sheets, rolled and stretched with advanced welding. Automatic overflow protection when water level exceeds limit. Airtight seals on body and lid.
  • Steam blocking cap: Prevents steam from entraining water droplets, improving distillate purity.
  • Condenser: Stainless steel coils with high heat exchange rate; easily removable for descaling.
  • Heating system: Immersed T4 copper-sheathed electric heating tube, tin-plated surface, mounted at evaporator bottom.
  • Drain cock: Right side of evaporator allows convenient draining and storage water removal.
  • Water cut-off protection (optional): Automatically cuts power when water supply fails or tank is empty.

Ordering Information

Cat. No.DescriptionPackaging
18251001Laboratory Water Distiller, 3L/H, Standard, Stainless Steel, 110V/220V, 2.5KW1 set/carton
18251002Laboratory Water Distiller, 3L/H, Water Cut-off Protection, Stainless Steel, 110V/220V, 2.5KW1 set/carton
18251003Laboratory Water Distiller, 5L/H, Standard, Stainless Steel, 110V/220V, 4.5KW1 set/carton
18251004Laboratory Water Distiller, 5L/H, Water Cut-off Protection, Stainless Steel, 110V/220V, 4.5KW1 set/carton
18251005Laboratory Water Distiller, 10L/H, Standard, Stainless Steel, 380V, 7.5KW1 set/carton
18251006Laboratory Water Distiller, 10L/H, Water Cut-off Protection, Stainless Steel, 380V, 7.5KW1 set/carton
18251007Laboratory Water Distiller, 20L/H, Standard, Stainless Steel, 380V, 13.5KW1 set/carton
18251008Laboratory Water Distiller, 20L/H, Water Cut-off Protection, Stainless Steel, 380V, 13.5KW1 set/carton

Frequently Asked Questions

What is the difference between a water distiller and a deionizer?

A water distiller boils water to remove minerals, bacteria, and pyrogens via phase change; a deionizer uses ion exchange resins to remove charged ions. Distillers are better for removing non-ionic contaminants and producing pyrogen-free water.

What is the purity of distilled water from this unit?

Conductivity typically < 5 µS/cm, meeting CLSI Type III water standards. For higher purity (Type I), an additional polishing step is recommended.

How often does the unit need descaling?

Frequency depends on feed water hardness. In areas with hard water, descaling every 2-4 weeks is recommended. The stainless steel construction allows safe use of descaling acids (e.g., citric acid).

Can I run the distiller continuously?

Yes, the unit is designed for continuous operation. However, water cut-off protection models are safer for unattended long runs.

What voltage options are available?

110V/220V for 3L/H and 5L/H models; 380V for 10L/H and 20L/H models. Please specify voltage when ordering.

Trust & Support – Why Hawach

  • CE certified– meets European safety standards for laboratory equipment.
  • Factory direct– competitive pricing, technical support, and spare parts supply.
  • Global shipments– exported to 50+ countries with local distributors.
  • Spare parts in stock– heating elements, seals, drain cocks, and gaskets.

Note: Specifications are subject to change without notice. For the latest information, contact info@hawach.com. Hawach Laboratory Water Distillers are independently manufactured and comply with international quality standards.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation