HILIC Amide Column

USP L68
5 μm
120Å
pH 2.0-8.0
LC/MS Compatible

Availability: In Stock

Category:

Description

A HILIC amide column (Hydrophilic Interaction Liquid Chromatography amide column) is a polar stationary phase designed to retain and separate hydrophilic compounds that are poorly retained or elute at the void volume on conventional reversed-phase C18 columns. The amide-bonded phase offers strong hydrogen bonding and dipole interactions, providing excellent retention for carbohydrates, polar metabolites, peptides, glycans, and small polar drugs.

Hawach HILIC amide columns are manufactured from ultra-pure porous spherical silica gel (≥ 99.999%) with a chemically bonded carbamoyl (amide) functional group. Compared to bare silica (USP L3) and amino (NH₂, USP L8) phases, the amide column is electrically neutral, more stable, and free from Schiff base reactions with reducing sugars. It delivers longer column lifetime, better batch-to-batch reproducibility, and superior peak shapes for a wide range of polar analytes.

This column is classified as USP L68 and is a direct performance alternative to Waters XBridge Amide, Thermo Accucore Amide HILIC, and Agilent Zorbax HILIC Plus. It is fully compatible with LC/MS, ELSD, CAD, and UV detection.

Why Polar Compounds Fail on C18 Columns

Hydrophilic compounds such as sugars, amino acids, nucleotides, and polar metabolites often show little or no retention on conventional reversed-phase C18 columns. They elute near the void volume with poor resolution and weak MS response.

HILIC amide columns solve this limitation by using:

  • strong polar interaction retention
  • high-organic mobile phase systems
  • orthogonal selectivity versus reversed-phase methods

Resulting in:

  • stronger retention
  • improved separation
  • enhanced LC/MS sensitivity
  • higher reproducibility for polar analytes

Why Choose a HILIC Amide Column Over Other Polar Phases

FeatureHILIC Amide (USP L68)Bare Silica (USP L3)Amino NH₂ (USP L8)
Retention mechanismHydrogen bonding + partitioningMixed silanol interactionsWeak anion exchange
Stability with reducing sugarsExcellentModeratePoor
Batch reproducibilityVery highVariableModerate
Column lifetimeLongModerateShort
LC/MS compatibilityExcellentGoodModerate
Equilibration timeFastModerateSlow
Best forCarbohydrates, glycans, metabolites, peptidesGeneral HILICLegacy sugar methods

Key takeaway: HILIC amide provides the most stable and LC/MS-friendly performance for polar separations.

HILIC-Amide-HPLC

Amide vs ZIC-HILIC

PhaseChargeTypical Use
AmideNeutralSugars, glycans, polar compounds
ZIC-HILICZwitterionicIonic metabolites, phosphates
NH₂Weakly basicLegacy carbohydrate methods

Quick Selection Guide

ApplicationRecommended Part No.Particle SizeID × LengthWhy
Routine polar compound QC130213955 μm4.6 × 250 mmHighest resolution standard
Faster analysis130213945 μm4.6 × 150 mmShorter run time
High-throughput screening130213935 μm4.6 × 100 mmFast equilibration

Core Technical Specifications

ParameterValue
USP classificationL68
Bonded phaseCarbamoyl (amide) functional group
Particle size5 μm
Pore size120Å
Surface area~320 m²/g
Carbon load~7%
pH range2.0-8.0
Max pressure~4000 psi
Temperature≤60°C
Mobile phaseAcetonitrile/water or buffer (70-95% ACN)
Flow rate1.0 mL/min (4.6 mm ID)
DetectorsLC/MS, ELSD, CAD, RI, UV
End-cappingNot applicable

Order Information

Cat#DescriptionPackage (pcs/pk)
13021393HPLC Column, HILIC Amide, 5 μm, 120Å, 4.6 × 100 mm1
13021394HPLC Column, HILIC Amide, 5 μm, 120Å, 4.6 × 150 mm1
13021395HPLC Column, HILIC Amide, 5 μm, 120Å, 4.6 × 250 mm1

Recommended standard model:

13021395 – HILIC Amide, 5 μm, 120Å, 4.6 × 250 mm
Most widely used configuration for routine HILIC applications.
Download PDF Datasheet

Typical Applications

IndustrySample TypePurpose
Carbohydrates & sugarsMono-, di-, oligosaccharidesStrong retention, no Schiff base reaction
PharmaceuticalPolar metabolitesLC/MS compatible analysis
BiopharmaGlycopeptides, glycansGlycosylation profiling
MetabolomicsAmino acids, nucleotidesPolar profiling
FoodVitamins, additivesNutritional analysis
EnvironmentalPolar pesticidesOrthogonal separation
Natural productsGlycosides, alkaloidsPolar compound separation

How HILIC Amide Columns Work

Retention in HILIC mode is driven by:

  • hydrogen bonding interactions
  • dipole-dipole interactions
  • partitioning into a water-enriched layer on the stationary phase

High organic mobile phase (70-95% acetonitrile) enhances retention and improves MS sensitivity.

Mobile Phase Guidelines

Recommended:

  • ≥70% acetonitrile
  • ammonium acetate / ammonium formate (LC/MS)
  • phosphate buffer (UV only)

Not recommended:

  • 30% water
  • pH >8
  • 100% aqueous mobile phase

Manufacturing & Quality System

  • ISO 9001 certified production
  • Ultra-high purity silica (>99.999%)
  • Controlled amide bonding process
  • Batch-tested with polar standards
  • COA and chromatogram included
  • Full traceability
  • OEM and private label available

Compatibility with Major Brand Methods

Standard ColumnCompatibility
Waters XBridge AmideDirect replacement
Thermo Accucore Amide HILICEquivalent performance
Agilent Zorbax HILIC PlusDirect replacement
Phenomenex Luna HILICComparable performance
USP L68 methodsFully compliant

Procurement Advantages

  • Lower cost versus major brands
  • Direct method replacement in most QC workflows
  • Stable inventory for standard SKUs
  • Full COA and chromatogram per batch
  • OEM and private label support
  • Fast shipping for standard models (3-5 days)
  • High batch-to-batch reproducibility

Frequently Asked Questions

What is the difference between HILIC amide and C18?

HILIC amide retains polar compounds using high-organic mobile phases, while C18 retains non-polar compounds using aqueous systems.

Why use amide instead of NH2?

Amide phases are more stable, LC/MS friendly, and do not form Schiff bases with reducing sugars.

Is it suitable for carbohydrates?

Yes, it is widely used for carbohydrate and glycan analysis.

USP classification?

USP L68.

LC/MS compatibility?

Yes, excellent compatibility with volatile buffers.

OEM availability?

Yes, OEM and custom manufacturing are available.