Large-Volume Bioprocessing Flask for High-Throughput Cell Harvesting & Industrial Fermentation
Availability: In Stock
Large-Volume Bioprocessing Flask for High-Throughput Cell Harvesting & Industrial Fermentation
Availability: In Stock
For laboratories scaling from benchtop to production, Hawach 500 mL centrifuge bottles close the gap between small-volume R&D and industrial bioprocessing. Manufactured from high-purity virgin polypropylene in ISO cleanroom environments, these bottles are designed for high-throughput cell harvesting, large-scale microbial precipitation, and upstream bioprocess sample concentration.
Validated to 6,000 ×g under full rotor support, the 500 mL format fits standard large-volume centrifuge rotors from leading brands. Each bottle is factory sterilized and certified non-pyrogenic, ready for direct use in regulated biopharma workflows.
Unlike smaller 250 mL bottles, the 500 mL version is optimized for:
| Item | Specification |
| SKU Number | 11351002 |
| Nominal Volume | 500 mL |
| Product Type | Large-volume centrifuge flask / bottle |
| Maximum Validated RCF | 6,000 ×g |
| Material | High-purity virgin polypropylene |
| Cap Type | Leak-resistant screw cap |
| Sterility Grade | Factory sterilized (E-beam) |
| Biological Grade | Non-Pyrogenic |
| Temperature Resistance | -80°C to +121°C |
| Packaging | 2 pcs/bag, 20 bags/carton (40 pcs/carton total) |
| Typical Applications | Bulk cell harvesting, fermentation concentration, large-scale protein precipitation, bioprocess QC |
| Problem | Solution in Hawach 500 mL Bottle | Outcome | Impact |
| Too many centrifuge runs per harvest batch | 500 mL single-bottle capacity | 2.5× fewer runs compared to 200 mL bottles | High (time & energy saving at scale) |
| Bottle deformation under full load at 6,000 ×g | Reinforced wall geometry for 500 mL volume | Stable structure, no bulging, consistent pellet formation | High (reproducibility in production) |
| Cross-batch pyrogen variability | Non-pyrogenic grade with lot-specific testing | Meets biopharma QC release criteria | High (regulatory compliance) |
| Bottles not stackable for freezer storage | Uniform external geometry with flat top | Stackable 3-4 high, saves freezer space | Medium (laboratory organization) |
| Scaling from R&D to production requires new validation | Same material, same RCF rating as 250 mL version | Direct scale-up – no revalidation needed | High (seamless process transfer) |
Industrial and high-throughput labs face unique challenges when moving beyond 250 mL:
Hawach 500 mL centrifuge bottles are engineered specifically to eliminate these scaling frictions.
| Rotor Type | Compatibility | Notes |
| Swing Bucket Rotor (500 mL buckets) | Fully compatible | Standard bucket depth accepts 500 mL bottle height |
| Fixed Angle Rotor (500 mL cavities) | Fully compatible | 45° angle typical; no adapter required |
| 250 mL Rotors | Not compatible | Physical dimensions differ – do not force fit |
Major brand rotor systems validated:
Always confirm rotor model. Free rotor compatibility verification available upon request.
Hawach 500 mL centrifuge bottles are dimensionally and functionally equivalent to:
Seamless drop-in replacement – no rotor adjustment, no cap adapter, no workflow retraining.
| Temperature Condition | Performance |
| Ultra-low freezer (-80°C) | Stable, no cracking; supports long-term biobanking |
| Standard autoclaving (121°C, 20 min) | Fully compatible |
| Freeze-thaw cycling (x10 cycles) | No loss of mechanical integrity |
| Working temperature range | +4°C (cold room) to +50°C (warm buffers) |
Note: For critical high-speed centrifugation, single-use after autoclaving recommended.
Compatible With (typical bioprocess reagents)
Not Recommended For
For aggressive solvent applications, contact technical support for material upgrade options.
Test conditions follow ISO-like centrifugation guidelines for large-volume bioprocessing rotors (6,000 ×g, 500 mL rated fill, room temperature, standard biological broth). Internal validation protocol for industrial-grade benchmark definition.*
| Performance Metric | Generic 500 mL Bottles | Hawach 500 mL Bottles |
| Leakage at 6,000 ×g | Occasional visible wetness | No leakage observed under test |
| Wall deformation at full load | Bulging visible in 20% of runs | No deformation |
| Stackability for -80°C storage | Not stackable (rounded top) | Stackable (flat-top design) |
| Bioburden after sterilization | Variable (0.1-1% positive) | Consistent sterility SAL 10⁻⁶ |
| Batch-to-batch dimensional tolerance | ±2% variation | ±0.5% (injection molding control) |
| Attribute | Specification |
| SKU Number | 11351002 |
| Nominal Volume | 500 mL |
| Product Name | 500 mL Centrifuge Flask / Bottle |
| Biological Grade | Non-Pyrogenic |
| Sterility | Factory sterilized (E-beam, SAL 10⁻⁶) |
| Maximum Validated RCF | 6,000 ×g |
| Raw Material | High-purity virgin polypropylene |
| Cap Design | Leak-resistant screw cap, 45 mm neck diameter |
| Temperature Range | -80°C to +121°C |
| Outer Diameter (approx.) | 78 mm |
| Height (approx.) | 168 mm |
| Bottle Shape | Cylindrical with conical bottom |
| Graduations | Molded, every 50 mL |
| Writing Area | Frosted panel for labeling |
| Rotor Fit | Swing bucket & fixed angle 500 mL cavities |
| Packaging | 2 pieces/bag, 20 bags/carton (40 pieces total) |
| Carton Dimensions (approx.) | 45 x 35 x 28 cm |
| Gross Weight per Carton | ~6.5 kg (with bottles) |
| Volume | Max RCF | Sterility | Application |
| 50 mL centrifuge tubes | 12,000 ×g | Sterile | routine molecular biology |
| 250 mL centrifuge bottles | 6,000 ×g | Sterile | bioprocessing |
| 500 mL centrifuge bottles | 6,000 ×g | Sterile | large-volume harvesting |
Used for: Harvesting 5-50 L bioreactor cultures, concentrating fermentation broths, collecting secreted proteins or exosomes.
– Outcome: Reduce centrifuge runs by 50% compared to 250 mL bottles; transfer directly from R&D to production without revalidation.
Used for: Large-volume suspension cell harvesting (CHO, HEK293, Vero cells), lentiviral vector concentration, media clarification.
– Outcome: Maintain non-pyrogenic integrity across hundreds of bottles per batch; stackable design doubles -80°C storage density.
Used for: Biomass collection from 20 L to 200 L fermentation trains, spore harvesting, bacterial cell banking.
– Outcome: Consistent structural performance under repeated high-volume centrifugation; lot traceability meets ISO 9001 audit requirements.
Used for: Bulk sample preparation for endotoxin testing, bioburden analysis, host cell protein (HCP) assays.
– Outcome: Pre-sterilized, ready-to-use format reduces QC lab prep time; non-pyrogenic certification supports regulatory filing.
| Catalog Number | Description | Packaging |
| 11351002 | 500 mL Centrifuge Bottle, Sterilized, Non-Pyrogenic | 2 pcs/bag, 20 bags/carton (40 pcs/carton total) |
Why 2 pcs/bag? – Double-bagged format reduces contamination risk when opening a carton; each bag contains a matched pair for paired rotor balancing.
Alternative packaging available upon request:
Available services for high-volume buyers:
| Service | Availability |
| Custom logo printing (bottle side) | MOQ 5,000 pieces per design |
| Private label carton | MOQ 1,000 cartons |
| Barcode labeling (custom SKU) | MOQ 10,000 pieces |
| Distributor reserved stocking | Negotiated annually |
| Lot-specific COA & sterility certificates | Provided for every batch |
| Long-term fixed pricing (1-3 years) | For annual volumes ≥20,000 pieces |
A: The 500 mL bottle has a larger diameter and taller height, requiring specific 500 mL rotor buckets. It is not a scaled-up 250 mL shape but a separate industrial format.
A: No. The dimensions are incompatible. Always use 500 mL-rated rotors.
A: Yes, under standard conditions with supported rotor buckets. For fixed-angle rotors, we recommend ≤450 mL fill to account for meniscus effect.
A: Yes, each batch is tested for nuclease-free and endotoxin-free. COA available.
A: Yes, but inspect for cracks after thawing. Single freeze-thaw cycle is fine; repeated cycles may weaken polypropylene.
A: Screw until finger-tight, then an additional quarter-turn. Do not over-tighten (can crack threads).
A: One carton (40 pieces). Smaller sample packs available upon request.
A: Yes, for distributor orders. Contact for pallet configuration.
A: Yes, specify non-sterile when ordering. Lead time shorter (3-5 days).
A: Yes, tiered pricing available. Request a volume quote.
A: Yes, included with each batch. Additional validation reports available upon request.
For process development labs: Request up to 10 free evaluation bottles (sterile, non-pyrogenic) for rotor fit and performance testing.
For procurement teams: Submit your annual volume (pieces or cartons) and packaging preference. Receive tiered pricing, lead time confirmation, and sample COA within 24 hours.
For distributors: Inquire about regional exclusivity, stocking programs, and private label OEM.

The quality has a guarantee
Fast & safe shipping worldwide