+86-29-89284429

Regenerated Cellulose (RC) Syringe Filters – Sterile & Non-Sterile

Filter Media: Regenerated Cellulose Memebrane
Dia: 13mm, 25mm, 33mm, 50mm
Pore Size: 0.22μm, 0.45μm

Availability: In Stock

Description

Hydrophilic Low Binding Filtration for Aqueous & Sensitive Samples

Hawach regenerated cellulose (RC) syringe filters are hydrophilic, low protein binding membrane filters designed for aqueous solutions, biological samples, and sensitive analytical applications. Compared with general filtration membranes, RC filters provide ultra-low protein adsorption for high sample recovery, hydrophilic structure for direct water-based filtration, very low extractables for clean analytical results, stable flow performance for routine lab workflows, and sterile/non-sterile options for different applications.

Ideal for HPLC aqueous sample prep, biological fluids, and sensitive laboratory filtration.

Recommended Choice for Sensitive Aqueous & Biological Samples

0.22 µm Sterile RC Syringe Filter

  • Ultra-low protein binding membrane – high recovery of antibodies, enzymes, and growth factors
  • Gamma sterilized (SAL 10⁻⁶) – ready-to-use for aseptic workflows
  • Very low extractables – clean HPLC baselines
  • High recovery for biological molecules – validated low adsorption

Best choice for cell culture media, protein solutions, and sterile aqueous filtration

Quick Selection Guide (3-Second Decision)

Use CaseRecommended SeriesPore Size
Sterile biological filtrationSterile RC0.22 µm
Protein / enzyme sample prepSterile RC0.22 µm
General aqueous clarificationStandard RC0.45 µm
Pre-analysis sample filtration (HPLC)Standard or Sterile RC0.22–0.45 µm
Gas / air ventingRC Vent Filter0.22–0.45 µm

Applications

Regenerated cellulose syringe filters are widely used in:

  • HPLC / UHPLC aqueous sample preparation
  • Protein and enzyme solution filtration
  • Biological fluid clarification
  • Cell culture media filtration
  • Pharmaceutical aqueous QC testing
  • Environmental water analysis
  • General laboratory sample preparation

Product Configuration Options

TypeSterilityPositioningApplication
Standard RCNon-sterileAnalytical gradeRoutine aqueous filtration
Sterile RCGamma sterileBio/pharma gradeCell culture & microbiology
RC Vent FilterSterileGas/air filtrationSterile venting applications

Key Features

  • Hydrophilic membrane – no pre-wetting required, direct aqueous filtration
  • Ultra-low protein binding – high recovery of biomolecules (validated >95% for BSA)
  • Very low extractables – clean chromatographic results (HPLC certified)
  • Fast flow rate – efficient sample processing
  • Broad aqueous compatibility – ideal for water-based solutions
  • Sterile option available – gamma irradiation (SAL 10⁻⁶)
  • Low endotoxin – < 0.25 EU/mL (sterile series)

Technical Specifications

ParameterSpecification
Membrane MaterialRegenerated Cellulose (RC)
TypeHydrophilic
Pore Sizes0.22 / 0.45 µm
Diameters13 / 25 / 33 / 50 mm
HousingMedical-grade polypropylene (PP)
Max Operating Pressure≤ 5.2 bar (approx. 75 psi)
Temperature RangeUp to 60°C
Sterility (Sterile Series)Gamma irradiation (SAL 10⁻⁶)
Endotoxin Level< 0.25 EU/mL (sterile series)
Protein BindingVery low (validated for BSA, IgG)
ExtractablesUltra-low extractables for clean chromatographic results (210–254 nm)

Detailed SKU & Ordering Information

Most popular for labs: 11108403 / 11108405 (0.22 µm sterile)

Sterile Regenerated Cellulose Syringe Filters (Pharma & Biotech Grade)

Item CodePore Size(µm)Diameter(mm)SterileQuantity/pk
111084030.22100Gamma sterile100
111084040.45100Gamma sterile100
111084050.22100Gamma sterile100
111084060.45100Gamma sterile100
111084070.2250Gamma sterile50
111084080.4550Gamma sterile50
111084090.2225Gamma sterile25
111084100.4525Gamma sterile25

RC Vent Filters (Non-Sterile, for Gas/Air Venting)

Item CodePore Size(µm)Diameter(mm)SterileQuantity/pk
111042030.2213NO100
111042040.4513NO100
111042050.2225NO100
111040080.4525NO100
111042070.2233NO50
111042080.4533NO50
111042090.2250NO25
111042100.4550NO25

Custom options: Other diameters (4 mm, 50 mm) and pore sizes available upon request. Contact sales for OEM and private label.

RC vs Other Membrane Filters

MembraneStrengthBest UseLimitation
RCUltra-low binding, low extractablesSensitive aqueous & biological samplesNot for organic solvents
CALow protein bindingGeneral biological filtrationNot for solvents
PESVery high performance, ultra-low bindingProtein/biotech applicationsNot for solvents
PTFEChemical resistanceOrganic solvents, gasesRequires pre-wetting for water

For general biological filtration – CA Syringe Filters

For ultra-low protein binding workflows – PES Syringe Filters

For solvent filtration – PTFE Syringe Filters

Why Choose Hawach RC Syringe Filters?

FeatureBenefit
Ultra-low protein adsorptionMaximizes recovery of precious proteins and enzymes
Low extractables (HPLC certified)Clean chromatographic baselines, no ghost peaks
High recovery for biological samplesValidated >95% for model proteins
Hydrophilic, no pre-wettingDirect use for aqueous solutions – saves time
Sterile options (gamma irradiated)Ready for cell culture and aseptic processing
CE / 9001 certifiedBatch-to-batch consistency and traceability

Quality & Manufacturing Assurance

  • CE& ISO 9001 certified production
  • ISO Class 7 cleanroom for sterile series manufacturing
  • Gamma sterilization – Sterility Assurance Level (SAL) 10⁻⁶
  • Endotoxin tested – < 0.25 EU/mL (sterile series)
  • Low extractables validated – by HPLC (210–254 nm)
  • Protein binding validated – typical recovery > 95% for BSA and IgG
  • Batch traceability – each lot tested for integrity and performance
  • 100% integrity testing – no leakage or membrane defects

Frequently Asked Questions (FAQ)

What is regenerated cellulose syringe filter used for?

It is used for aqueous and biological sample filtration, especially protein, enzyme, and cell culture media preparation, as well as HPLC sample prep where low extractables are critical.

Is RC membrane low protein binding?

Yes, RC has very low protein adsorption (validated >95% recovery) and is ideal for high-recovery applications.

Can RC filters be used for organic solvents?

No. RC is designed for aqueous solutions only. For organic solvents, use PTFE syringe filters.

What pore size is used for sterile filtration?

0.22 µm is the standard for sterile filtration and bacterial removal (SAL 10⁻⁶).

What is an RC vent filter used for?

It is used for sterile gas and air venting applications (e.g., bioreactor inlet/outlet, sterile container vents).

What is the difference between RC and CA/PES filters?

  • RC: Ultra-low protein binding + very low extractables – best for HPLC and sensitive biomolecule recovery.
  • CA: Low protein binding, cost-effective, general biological use.
  • PES: High flow, ultra-low binding, ideal for high-throughput protein filtration.

Can RC filters be autoclaved?

No, they are single-use. Sterile versions are gamma irradiated; do not autoclave.

Ordering & Customization

Hawach RC syringe filters are available in multiple pore sizes (0.22, 0.45 µm), diameters (13–50 mm), and sterility configurations. We support:

  • OEM / private label customization (logo, packaging, SKU)
  • Bulk supply for distributors and large laboratories
  • Fast global delivery from stock
  • Free samples for qualified customers

Request Technical Datasheet     Request Free Sample     Get Application Recommendation

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top