Filter Media: Regenerated Cellulose Memebrane
Dia: 13mm, 25mm, 33mm, 50mm
Pore Size: 0.22μm, 0.45μm
Availability: In Stock
Filter Media: Regenerated Cellulose Memebrane
Dia: 13mm, 25mm, 33mm, 50mm
Pore Size: 0.22μm, 0.45μm
Availability: In Stock
Hawach regenerated cellulose (RC) syringe filters are hydrophilic, low protein binding membrane filters designed for aqueous solutions, biological samples, and sensitive analytical applications. Compared with general filtration membranes, RC filters provide ultra-low protein adsorption for high sample recovery, hydrophilic structure for direct water-based filtration, very low extractables for clean analytical results, stable flow performance for routine lab workflows, and sterile/non-sterile options for different applications.
Ideal for HPLC aqueous sample prep, biological fluids, and sensitive laboratory filtration.
Best choice for cell culture media, protein solutions, and sterile aqueous filtration
| Use Case | Recommended Series | Pore Size |
| Sterile biological filtration | Sterile RC | 0.22 µm |
| Protein / enzyme sample prep | Sterile RC | 0.22 µm |
| General aqueous clarification | Standard RC | 0.45 µm |
| Pre-analysis sample filtration (HPLC) | Standard or Sterile RC | 0.22–0.45 µm |
| Gas / air venting | RC Vent Filter | 0.22–0.45 µm |
Regenerated cellulose syringe filters are widely used in:
| Type | Sterility | Positioning | Application |
| Standard RC | Non-sterile | Analytical grade | Routine aqueous filtration |
| Sterile RC | Gamma sterile | Bio/pharma grade | Cell culture & microbiology |
| RC Vent Filter | Sterile | Gas/air filtration | Sterile venting applications |
| Parameter | Specification |
| Membrane Material | Regenerated Cellulose (RC) |
| Type | Hydrophilic |
| Pore Sizes | 0.22 / 0.45 µm |
| Diameters | 13 / 25 / 33 / 50 mm |
| Housing | Medical-grade polypropylene (PP) |
| Max Operating Pressure | ≤ 5.2 bar (approx. 75 psi) |
| Temperature Range | Up to 60°C |
| Sterility (Sterile Series) | Gamma irradiation (SAL 10⁻⁶) |
| Endotoxin Level | < 0.25 EU/mL (sterile series) |
| Protein Binding | Very low (validated for BSA, IgG) |
| Extractables | Ultra-low extractables for clean chromatographic results (210–254 nm) |
| Item Code | Pore Size(µm) | Diameter(mm) | Sterile | Quantity/pk |
| 11108403 | 0.22 | 100 | Gamma sterile | 100 |
| 11108404 | 0.45 | 100 | Gamma sterile | 100 |
| 11108405 | 0.22 | 100 | Gamma sterile | 100 |
| 11108406 | 0.45 | 100 | Gamma sterile | 100 |
| 11108407 | 0.22 | 50 | Gamma sterile | 50 |
| 11108408 | 0.45 | 50 | Gamma sterile | 50 |
| 11108409 | 0.22 | 25 | Gamma sterile | 25 |
| 11108410 | 0.45 | 25 | Gamma sterile | 25 |
| Item Code | Pore Size(µm) | Diameter(mm) | Sterile | Quantity/pk |
| 11104203 | 0.22 | 13 | NO | 100 |
| 11104204 | 0.45 | 13 | NO | 100 |
| 11104205 | 0.22 | 25 | NO | 100 |
| 11104008 | 0.45 | 25 | NO | 100 |
| 11104207 | 0.22 | 33 | NO | 50 |
| 11104208 | 0.45 | 33 | NO | 50 |
| 11104209 | 0.22 | 50 | NO | 25 |
| 11104210 | 0.45 | 50 | NO | 25 |
Custom options: Other diameters (4 mm, 50 mm) and pore sizes available upon request. Contact sales for OEM and private label.
| Membrane | Strength | Best Use | Limitation |
| RC | Ultra-low binding, low extractables | Sensitive aqueous & biological samples | Not for organic solvents |
| CA | Low protein binding | General biological filtration | Not for solvents |
| PES | Very high performance, ultra-low binding | Protein/biotech applications | Not for solvents |
| PTFE | Chemical resistance | Organic solvents, gases | Requires pre-wetting for water |
For general biological filtration – CA Syringe Filters
For ultra-low protein binding workflows – PES Syringe Filters
For solvent filtration – PTFE Syringe Filters
| Feature | Benefit |
| Ultra-low protein adsorption | Maximizes recovery of precious proteins and enzymes |
| Low extractables (HPLC certified) | Clean chromatographic baselines, no ghost peaks |
| High recovery for biological samples | Validated >95% for model proteins |
| Hydrophilic, no pre-wetting | Direct use for aqueous solutions – saves time |
| Sterile options (gamma irradiated) | Ready for cell culture and aseptic processing |
| CE / 9001 certified | Batch-to-batch consistency and traceability |
It is used for aqueous and biological sample filtration, especially protein, enzyme, and cell culture media preparation, as well as HPLC sample prep where low extractables are critical.
Yes, RC has very low protein adsorption (validated >95% recovery) and is ideal for high-recovery applications.
No. RC is designed for aqueous solutions only. For organic solvents, use PTFE syringe filters.
0.22 µm is the standard for sterile filtration and bacterial removal (SAL 10⁻⁶).
It is used for sterile gas and air venting applications (e.g., bioreactor inlet/outlet, sterile container vents).
No, they are single-use. Sterile versions are gamma irradiated; do not autoclave.
Hawach RC syringe filters are available in multiple pore sizes (0.22, 0.45 µm), diameters (13–50 mm), and sterility configurations. We support:
Request Technical Datasheet Request Free Sample Get Application Recommendation

The quality has a guarantee
Fast & safe shipping worldwide