ISO 12771
Orange Color Code
Welded Tip
Gamma Irradiated
DNase/RNase-Free
Endotoxin-Free
Availability: In Stock
ISO 12771
Orange Color Code
Welded Tip
Gamma Irradiated
DNase/RNase-Free
Endotoxin-Free
Availability: In Stock
Hawach individually wrapped sterile serological pipettes solve these issues – open one at a time, keep the rest sealed, and transfer aseptically into laminar flow hoods, significantly reducing contamination risk. The 10 mL size is the go-to pipette for larger-volume cell culture tasks such as feeding 75 cm² or 175 cm² flasks, preparing bulk media, and transferring larger sample volumes in QC and production workflows.
The 10 mL serological pipette – also referred to as a 10 mL cell culture pipette or sterile 10 mL serological pipette – is a precision disposable pipette designed for aseptic liquid handling where volumes of 5-10 mL are routinely needed. Each pipette is individually wrapped in a sterile peel-pouch, allowing you to open only what you need – ideal for GMP-controlled workflows and busy biosafety cabinets.
Hawach’s 10 mL sterile disposable pipette (Cat# 21111004) meets ISO 12771, features a welded tip for added strength and consistent internal diameter, and is color-coded orange for easy size identification (standard for 10 mL). It is gamma irradiated (SAL 10-⁶), certified non-pyrogenic, DNase/RNase-free, and endotoxin-free. The larger inner diameter (Φ10 mm) provides very fast liquid uptake, and the extended length (344.85 mm) ensures excellent media bottle access – you can reach the bottom of 500 mL or 1 L bottles without tipping, significantly reducing spill risk during large-volume transfers.
Key advantage: Individual sterile packaging minimizes contamination exposure and waste – a critical upgrade from bulk-packed alternatives. The 10 mL format is the workhorse for routine media exchange in larger culture vessels (75 cm², 175 cm² flasks), bulk reagent preparation, and high-throughput liquid handling where 10 mL volumes are standard.
For cell therapy, vaccine production, and clinical diagnostics, individually wrapped serological pipettes are the standard over bulk-packed. The 10 mL cell culture pipette is especially popular for routine passage of cells in larger vessels, bulk media preparation, and any workflow requiring 10 mL transfers.
Compatible with all major serological pipettors and electronic controllers:
| Brand | Compatible? |
| Eppendorf | Yes |
| Thermo Scientific | Yes |
| Sartorius | Yes |
| Brand | Yes |
| Gilson | Yes |
| Rainin | Yes |
| Other standard 1-10 mL controllers | Yes |
Fits standard top diameter for 10 mL serological pipettes. No adapters needed. The longer length (344.85 mm) is designed to reach the bottom of deep vessels while maintaining compatibility with standard pipettors.
| Feature | Individually Wrapped (Hawach) | Bulk–Packed |
| Sterility after first opening | High – each pipette sealed | Medium – remaining pipettes exposed |
| Aseptic transfer into BSC | Easy – open pouch inside hood | Difficult – must handle carefully |
| Cross-contamination risk | Low | Higher |
| Suitable for GMP / regulated labs | Yes | Limited |
| Waste from unused pipettes | None | Some |
| Cost per pipette | Moderate (value for sterility) | Lower (but higher indirect costs) |
Conclusion: For aseptic cell culture and regulated workflows, individually wrapped pipettes provide superior sterility assurance.
| Parameter | Detail |
| Cat# | 21111004 |
| Volume | 10 mL |
| Graduation | 0.2 mL (typical) |
| Color code | Orange (ISO 12771 for 10 mL) |
| Tip design | Welded tip |
| Dimensions | Φ10 mm × 344.85 mm |
| Material | Polystyrene (PS) |
| Sterility | Gamma irradiated, SAL 10-⁶ |
| Purity | Non-pyrogenic, DNase/RNase-free, endotoxin-free (≤0.25 EU/mL) |
| Packaging | Individually wrapped peel-pouch; 50 pouches/bag; 4 bags/carton |
| Quantity per carton | 200 pipettes |
| Compliance | ISO 9001 certified |
| Area | Typical Use |
| Cell culture (larger flasks) | Feeding 75 cm² flasks (10 mL), 175 cm² flasks (20 mL with two pipettes), 100 mm dishes, adding buffers or trypsin to larger vessels |
| Bulk media & buffer prep | Transferring 10 mL aliquots, dilution series, reagent addition to 10 mL tubes |
| Molecular biology | PCR master mix (large reactions), nucleic acid precipitation (10 mL scale), enzyme preps |
| Clinical diagnostics | Serum/plasma transfers for 10 mL tubes, urine analysis, large-volume QC samples |
| Pharmaceutical QC | Reagent addition for 10 mL test volumes, dissolution sampling, bulk formulation |
| Microbiology | Inoculation of 10 mL broths, culture dilutions, McFarland standards |
| General lab | Large-volume serial dilutions, reagent prep, media aliquoting |
| Volume | Best Use | Typical Flask / Vessel |
| 1 mL | Small aliquots, enzyme addition | 96-well plate, small tubes |
| 2 mL | Routine small media changes, buffer addition | 25 cm² flask, 6-well plate |
| 5 mL | Standard media change, buffer addition | 25 cm² flask, 6-well plate, 60 mm dishes |
| 10 mL | Large-volume transfers, bulk media prep, feeding 75 cm² / 175 cm² flasks | 75 cm², 175 cm² flasks, 100 mm dishes, 500 mL-1 L bottles |
Hawach maintains consistent lot validation and traceable QC documentation, meeting the requirements of GMP, ISO, and regulatory audits.
| Specification | Detail |
| Primary | 1 pipette per sterile peel-pouch (paper-plastic) |
| Secondary | 50 pouches per inner bag |
| Tertiary | 4 bags per carton |
| Total per carton | 200 pipettes |
| Storage | Dry, 15-30 °C, away from sunlight |
Ordering: info@hawach.com. Free samples available for qualified labs.
Yes. For every production lot, we provide Certificate of Analysis (COA), sterility certificate, and endotoxin test report upon request.
Yes. Hawach serological pipettes are manufactured and packaged in ISO-classified cleanroom environments to ensure sterility and particulate control.
Yes. We offer OEM services including custom pouch printing (logo, part number, instructions), private label cartons, and custom bag counts. Minimum order quantity applies.
Typically 0.2 mL increments from 0 to 10 mL, plus negative graduations for blow-out delivery. Exact interval available on COA.
Yes. Fits all standard 1-10 mL serological pipettors from Eppendorf, Thermo, Sartorius, Brand, Gilson, Rainin, and others.
A welded tip is stronger and has a more consistent inner diameter than a stretched tip. It is less likely to break during aspiration of viscous liquids or when repeatedly inserting the pipette into bottles. The welded design also ensures more uniform flow characteristics across pipettes, improving volume accuracy.
75 cm² flasks typically require 10 mL of media for routine feeding, and 175 cm² flasks require 20 mL (two pipettes). The 10 mL pipette is also perfect for adding 10 mL of trypsin or buffer to 100 mm dishes. Its extended length (344.85 mm) allows easy access to the bottom of tall media bottles without tipping, making large-volume sterile transfers safer and more efficient.
Hawach supplies sterile individually wrapped serological pipettes for:
Available services:
Contact Hawach for quotation, validation documents, or free evaluation samples.
Email: info@hawach.com
Please include: laboratory name, application, estimated monthly usage (or carton quantity), and any specific packaging requirements.
We will respond with a targeted quote within 24 hours.

The quality has a guarantee
Fast & safe shipping worldwide