+86-29-89284429

Vortex Mixer

Touch operation or continuous operation
Variable speed control 0-2800 rpm
4 mm orbital motion
58W high-torque motor
Compact benchtop design
Interchangeable cup heads and foam inserts

Availability: In Stock

Description

Vortex mixers are essential laboratory instruments for rapid mixing, resuspension, and homogenization of small liquid volumes. Hawach vortex mixers combine variable speed vortex mixing, stable orbital motion, and workflow-compatible operation for molecular biology, clinical diagnostics, pharmaceutical QC, and environmental testing laboratories.

Designed for compatibility with common laboratory workflows, Hawach vortex mixers support a wide range of tube formats — from microcentrifuge tubes to 50 mL centrifuge tubes — with touch operation or continuous operation modes available. The 4 mm orbital motion generates rapid and uniform vortex formation for efficient liquid mixing while maintaining low vibration and stable operation.

Compatible with workflows commonly used on Thermo Fisher, IKA, and VWR vortex mixers.

Quick Selection Guide – Which Vortex Mixer Fits Your Workflow?

ApplicationRecommended ModelKey Features
Routine tube mixing, quick resuspension18102001Touch operation, 0-2800 rpm, 58W motor
Continuous mixing, unattended operation18102002Touch + continuous operation, variable speed control
Multiple tube sizes & accessory workflows18102003Includes tray platform and tray pad for extended applications
PCR master mix & DNA workflows18102001 + foam insertStable low-speed vortexing for sensitive molecular biology samples
Cell suspension & reagent preparation18102002Continuous operation with adjustable mixing intensity
General laboratory sample preparation18102002 / 18102003Compatible with microtubes, centrifuge tubes, and accessory inserts

Not sure which vortex mixer or accessory fits your workflow?
Email info@hawach.com with your tube size, application, and daily sample volume for configuration recommendations.

Protocol-Compatible with Thermo Fisher & IKA Vortex Mixers

Hawach vortex mixers are designed to be workflow-compatible with leading laboratory mixer brands:

  • Same tube cup geometry
  • Same orbital mixing intensity
  • Same touch and continuous operation logic
  • Same variable speed workflow
  • No method revalidation required
Competitor ModelHawach EquivalentCompatibility Features
Thermo Scientific LP Vortex Mixer18102002 / 18102003Same variable speed range, same touch/continuous operation
IKA MS3 Basic / MS3 Control18102002 / 18102003Same orbital mixing motion and accessory compatibility
VWR Analog/Digital Vortex Mixer18102001 / 18102002Similar operating workflow and tube compatibility

Cost-effective alternative with lower procurement cost compared to premium laboratory equipment brands.

What Is a Vortex Mixer?

A vortex mixer is a laboratory mixing instrument that creates rapid circular orbital motion to generate a vortex inside tubes or containers. This vortex action rapidly homogenizes liquids, suspensions, reagents, pellets, and biological samples.

Unlike orbital shakers or rockers designed for gentle long-duration mixing, vortex mixers deliver fast, localized high-speed mixing for individual laboratory tubes and small sample volumes.

Single-tube vortex mixers are commonly used for:

  • PCR preparation
  • DNA/RNA extraction
  • Cell pellet resuspension
  • Protein sample mixing
  • Solvent blending
  • Clinical reagent preparation
  • Chemical standard preparation
  • Bacterial suspension mixing

Key Specifications – Vortex Mixer

ParameterSpecification
Speed range0-2800 rpm (variable speed control)
Motion typeOrbital vortex mixing
Orbital diameter4 mm
Operating modesTouch operation / Continuous operation
Motor typeHigh-torque AC motor
Power consumption58 W
Voltage100-230 V, 50/60 Hz
AccessoriesStandard cup head, foam inserts, tray platform
Tube compatibilityMicrocentrifuge tubes, centrifuge tubes, vials, microplates
ConstructionCompact housing with anti-slip base

Technical Performance Features

  • Stable orbital vortex motion for uniform sample mixing
  • Optimized eccentric drive structure for smooth operation
  • Low vibration at high rpm
  • Continuous-duty motor design for extended operation
  • Heavy anti-slip zinc alloy base improves stability
  • Variable speed control for gentle or vigorous vortexing
  • Compact benchtop footprint for crowded laboratory workstations

Recommended Speed Guide

Sample Type / WorkflowRecommended Speed
PCR master mix1000-1500 rpm
DNA extraction1500-2000 rpm
Cell pellet resuspension500-1000 rpm
Protein solutions1000-1800 rpm
Viscous liquids2000-2800 rpm
QuEChERS extraction1500-2500 rpm
Reagent preparation1000-2000 rpm

Typical Applications of Vortex Mixers

Industry / WorkflowTypical UseRecommended Configuration
Molecular biology / PCRPCR master mix preparation, DNA pellet resuspension18102001 + foam insert
Cell cultureResuspending cells and media mixing18102002
Clinical diagnosticsBlood, serum, urine sample preparation18102001 / 18102002
Pharmaceutical QCDissolution testing and sample prep18102002 continuous operation
Food safety testingSample extraction and reagent mixing18102003
Environmental testingSoil and water extract preparation18102003
Protein workflowsProtein suspension and reagent blending18102002

Suitable for:

  • DNA/RNA samples
  • Protein solutions
  • Cell suspensions
  • Bacterial suspensions
  • Solvents and reagents
  • Chemical standards
  • Clinical specimens
  • Environmental extracts

Vortex Mixer for QuEChERS Extraction

Hawach vortex mixers are suitable for QuEChERS pesticide residue extraction workflows commonly used in food safety and environmental laboratories.

Typical applications include:

  • Acetonitrile extraction mixing
  • PSA / C18 / MgSO₄ dispersion
  • 15 mL and 50 mL centrifuge tube vortexing
  • Sample homogenization before LC-MS/MS analysis
  • Mycotoxin and pesticide residue preparation

Recommended mixing speed:

  • 1500-2500 rpm
  • 10-60 second vortex cycles depending on sample matrix

Why Procurement Teams Choose Hawach Vortex Mixers

  • Workflow-compatible with Thermo Fisher, IKA, and VWR systems
  • Variable speed vortex mixing from gentle resuspension to vigorous mixing
  • Touch operation and continuous operation modes available
  • Stable orbital motion with low vibration
  • Compatible with multiple tube sizes and accessories
  • Compact footprint for limited bench space
  • Continuous-duty motor suitable for routine laboratory use
  • In-stock standard models with fast shipment
  • OEM & private label support available
  • Distributor pricing and long-term supply support
  • Free evaluation units available for qualified laboratories

Ordering Information

Cat#DescriptionOperating ModesSpeed RangePowerIncluded Accessories
18102001Standard Vortex MixerTouch operation0-2800 rpm58 WStandard cup head
18102002Vortex MixerTouch + continuous operation0-2800 rpm58 WStandard cup head
18102003Vortex Mixer with tray platformTouch + continuous operation0-2800 rpm58 WTray platform, tray pad

Optional accessories:

  • Foam inserts for microtubes
  • 15 mL tube holders
  • 50 mL tube holders
  • Tray platforms
  • Custom accessory configurations

Frequently Asked Questions

Can Hawach vortex mixers replace Thermo Fisher or IKA models?

Yes. Hawach vortex mixers are workflow-compatible with major laboratory mixer brands, including similar orbital motion, operating modes, tube compatibility, and variable speed control. No method revalidation is normally required.

What is the difference between a vortex mixer and a shaker?

A vortex mixer generates localized high-speed orbital motion for rapid mixing of small liquid volumes in tubes. A shaker moves an entire platform in orbital or rocking motion for gentle long-duration mixing of multiple containers simultaneously.

Choose a vortex mixer for:

  • Pellet resuspension
  • Rapid reagent mixing
  • Small sample preparation

Choose a shaker for:

  • Cell culture
  • Blotting
  • Long-duration incubation mixing
Can a vortex mixer mix 50 mL centrifuge tubes?

Yes. Hawach vortex mixers can accommodate 50 mL centrifuge tubes using the standard cup head or optional tray accessories for improved stability during continuous operation.

What speed is recommended for DNA extraction?

Typical DNA extraction workflows use:

  • 1500-2000 rpm for pellet resuspension
  • 2000-2500 rpm for lysis mixing
  • Lower speeds for sensitive nucleic acid workflows

Always follow the extraction kit protocol when applicable.

Is continuous vortexing safe for cells?

Extended high-speed vortexing may damage sensitive cell membranes. For gentle cell suspension mixing, use lower vortex speeds or alternative mixing equipment such as rockers or orbital shakers.

Can the vortex mixer operate in cold rooms?

Yes. Hawach vortex mixers can operate in low-temperature laboratory environments. Confirm environmental requirements with the technical team for continuous cold-room applications.

Do you provide OEM or private label services?

Yes. OEM branding, custom packaging, distributor labeling, and accessory customization are available for distributors and laboratory suppliers.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top