+86-29-89284429

Cellulose Extraction Thimbles

  • 17×33 – 95×250 mm (30+ sizes)
  • Max 120°C
  • 8 µm pore size
  • 25 pcs/pack
  • Fat, Pesticide, PCB, Dioxin Extraction

Availability: In Stock

Description

What Are Cellulose Extraction Thimbles?

Extraction thimbles are cylindrical filter cartridges used in Soxhlet and similar extraction systems. Hawach cellulose extraction thimbles (also known as Soxhlet thimbles or cellulose extraction cartridges) are manufactured from high‑purity alpha cellulose without any binders. They are designed to hold solid samples while solvents percolate through, extracting target analytes such as fats, oils, pesticides, PCBs, and dioxins. With a nominal pore size of 8 µm and a maximum temperature of 120 °C, these thimbles offer excellent mechanical strength and consistent performance for routine analytical extractions.

Cellulose vs Glass Fiber Extraction Thimbles – Which to Choose?

FeatureCellulose Thimbles (Hawach)Glass Fiber Thimbles
Max temperature120°C (248°F) – routine organic solvents500°C – high‑temp & acidic gases
Chemical resistanceGood with organic solvents, oils, fats; degraded by strong acidsExcellent with most acids (except HF); limited alkali
Pore size8 µm (nominal)0.8 µm
Typical applicationsFat determination, pesticide residues, PCBs, dioxins, animal feedHigh‑temp Soxhlet, acidic gas sampling, gravimetric analysis
CostLower, economical for routine useHigher
Best forRoutine fat, oil, pesticide extraction at ≤120°CHigh‑temperature, acidic, or low‑background applications

Choose cellulose thimbles for routine Soxhlet extractions up to 120°C. Choose glass fiber thimbles for higher temperatures or aggressive acidic conditions.

Product Overview

  • Hawach cellulose extraction thimbles are produced from high‑alpha cellulose pulp with no binding elements. The cellulose thimble offers:
  • High purity (high alpha cellulose) – minimal background for accurate results.
  • Superior mechanical strength – resists tearing during handling and extraction.
  • Consistent porosity (8 µm) – fast solvent flow and efficient extraction.
  • Smooth interior and uniform wall thickness – perfect fit in extraction chambers.
  • Universal compatibility – works with Soxhlet, Tecator, and similar systems.

Detailed Specifications – Cellulose Extraction Thimbles

PropertyValue
MaterialHigh alpha cellulose (virgin pulp), binder‑free
Alpha cellulose contentHigh alpha cellulose
Ash contentLow ash
Pore size8 µm (nominal)
Maximum operating temperature120°C (248°F)
BinderNone
Extractable residueMinimal (high purity)
Packaging25 pcs per pack

Applications – Where Cellulose Extraction Thimbles Are Used

Fat Determination

Meat, dairy, food products (standard Soxhlet method).

Pesticide Residues

Extraction from food and agricultural samples.

PCB & Dioxin Analysis

Fish products and environmental samples.

Plasticizers

Phthalates from PVC.

Feed & Detergent Analysis

Additives in feed, organic compounds in detergents.

Air & Slurry Sampling

Dust collection, concrete slurry evaluation.

Environmental Testing

Oil & Grease Extraction, EPA methods.

Food Testing

Crude Fat Analysis, AOAC methods.

Complete Ordering Information – All Sizes

Cat. No.Size (OD×H mm)Wall Thickness (mm)Packaging
2203100117×331.0-1.525 pcs/pk
2203100219×901.5-2.025 pcs/pk
2203100322×601.5-1.7525 pcs/pk
2203100422×901.5-1.7525 pcs/pk
2203100525×801.5-1.7525 pcs/pk
2203100626×601.5-1.7525 pcs/pk
2203100727×801.5-2.025 pcs/pk
2203100828×701.5-2.025 pcs/pk
2203100928×1001.5-2.025 pcs/pk
2203103529×901.5-2.025 pcs/pk
2203101030×601.5-2.025 pcs/pk
2203101130×801.5-2.025 pcs/pk
2203101230×1001.5-2.025 pcs/pk
2203101333×601.5-2.025 pcs/pk
2203101433×801.5-2.025 pcs/pk
2203101533×941.5-2.025 pcs/pk
2203101634×801.5-2.025 pcs/pk
2203101734×1001.5-2.025 pcs/pk
2203101836×601.5-2.025 pcs/pk
2203101936×801.5-2.025 pcs/pk
2203102036×942.0-2.525 pcs/pk
2203102136×1002.0-2.525 pcs/pk
2203102237×1302.5-3.025 pcs/pk
2203102341×1202.5-3.025 pcs/pk
2203102441×1502.5-3.025 pcs/pk
2203102547×802.5-3.025 pcs/pk
2203102647×1232.5-3.025 pcs/pk
2203102758×1702.5-3.025 pcs/pk
2203102870×2402.5-3.025 pcs/pk
2203102980×2002.5-3.025 pcs/pk
2203103080×2502.5-3.025 pcs/pk
2203103195×2502.5-3.025 pcs/pk

Download PDF Datasheet

Why Choose Hawach Cellulose Extraction Thimbles?

Large Volume Filter Tips (5mL & 10mL) – Sterile, Brand-Specific Fit

Cat. No.VolumeCompatible PipetteDescriptionPackaging
210823015000μL (5mL)Thermo Fisher / BrandClear, sterile, non-pyrogenic600 (40pcs×15racks)
210823025000μL (5mL)Eppendorf / SartoriusClear, sterile, non-pyrogenic360 (24pcs×15racks)
2108230310000μL (10mL)Eppendorf / SartoriusClear, sterile, non-pyrogenic360 (24pcs×15racks)
2108230410000μL (10mL)Thermo Fisher / BrandClear, sterile, non-pyrogenic360 (24pcs×15racks)

Why Choose Hawach Filter Pipette Tips

  • High alpha cellulose – ultra‑low extractables
  • Binder‑free construction – no interference from adhesives
  • Consistent wall thickness – reliable fit and flow
  • Compatible with most Soxhlet extractors – including Tecator, Büchi, and traditional glass units
  • 30+ standard sizes – from 17×33 mm to 95×250 mm
  • Suitable alternative to Whatman extraction thimbles – verify dimensions for exact match
  • OEM and custom dimensions – available for volume orders
  • ISO 9001 certified manufacturing – consistent quality

Bulk Supply & OEM Services

Hawach offers comprehensive supply solutions for laboratories, distributors, and OEM customers:

OEM labeling – custom printing on packaging and private label
Custom dimensions – non‑standard sizes available upon request
Distributor support – bulk pricing, territory protection, and technical documentation
Export packaging – reinforced cartons for international shipping
COA available – batch‑specific certificates of analysis
Fast delivery – stock items ship within 3‑5 working days; bulk orders 2‑3 weeks

Contact us for a customized quote based on your annual volume and packaging preferences.

Selection Guide – How to Choose the Right Extraction Thimble Size

Extractor Type / Sample VolumeRecommended Size (OD×H mm)Typical Applications
Small Soxhlet (50‑100 mL flask)17×33, 22×60, 26×60, 30×60Small samples, pharmaceutical residues
Standard Soxhlet (150‑250 mL)25×80, 28×70, 30×80, 33×80, 36×80, 34×80Routine fat, pesticide, PCB extraction
Large capacity (500‑1000 mL)41×120, 41×150, 47×123, 58×170, 70×240Food industry, feed analysis, high sample load
Extra‑large / industrial80×200, 80×250, 95×250Bulk extraction, environmental samples

Fit tip: The thimble outer diameter should be 1‑2 mm smaller than the extractor chamber inner diameter. Height should be 5‑10 mm above the siphon tube top.

Instruction Drawing

Cellulose-Extraction-Thimbles-For-Soxhlet-Type-Tecator-Type-And-Similar-Devices-e1508387871108

Frequently Asked Questions – Cellulose Extraction Thimbles

What is the difference between cellulose extraction thimbles and glass fiber thimbles?

Cellulose thimbles are economical and ideal for routine solvent extractions at ≤120°C. Glass fiber thimbles withstand higher temperatures (500°C) and acidic gases, but cost more. See comparison table above.

Can I use cellulose thimbles with strong acids?

No. Strong acids degrade cellulose. For acidic samples or gaseous acids, use glass fiber thimbles.

What is the maximum temperature for cellulose extraction thimbles?

120°C (248°F). Exceeding this may cause charring.

What is the pore size of these thimbles?

Nominal 8 µm, retaining particles >8 µm while allowing fast solvent flow.

Are Hawach cellulose extraction thimbles compatible with Whatman extraction thimbles?

Yes. Hawach offers many dimensions that can replace Whatman thimbles. Always verify outer diameter and height before ordering.

What solvents can be used with cellulose extraction thimbles?

Common organic solvents: hexane, petroleum ether, acetone, toluene, dichloromethane, ethyl acetate, and alcohols. Avoid strong acids and bases.

Are cellulose extraction thimbles biodegradable?

Yes. Cellulose is biodegradable and can be disposed of as organic waste after extraction (ensure no hazardous residues).

Can extraction thimbles be reused?

Not recommended. Single‑use ensures no cross‑contamination and reliable results. Some labs rinse and reuse for non‑critical applications, but we advise fresh thimbles for each extraction.

What size extraction thimble do I need for my Soxhlet?

Measure the inner diameter of your extraction chamber; the thimble OD should be 1‑2 mm smaller. Height should be 5‑10 mm above the siphon tube top. See selection guide above.

Are cellulose extraction thimbles suitable for AOAC methods?

Yes. They are used in AOAC Official Methods for fat determination (e.g., AOAC 954.02, 960.39, 991.36).

Do you provide certificates of analysis (COA)?

Yes, batch‑specific COA for dimensions, porosity, ash content, and extractable residue available on request.

What is the ash content of Hawach cellulose thimbles?

Low ash – typically less than 0.2%, ensuring minimal interference in gravimetric analysis.

Can cellulose thimbles be used for dioxin analysis?

Yes. High‑purity cellulose thimbles are widely used for dioxin and PCB extraction from environmental samples.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top