+86-29-89284429

High Speed Centrifuge Bottles

250-1000 mL, Virgin Polypropylene, for Large-Volume High-Speed Workflows

Compatible with Beckman, Thermo, Sorvall rotors.

Availability: In Stock

Description

FieldValue
Product classificationlaboratory high-speed centrifuge bottle (250-1000 mL)
Material & designUSP Class VI virgin polypropylene, round body with reinforced base
Rated performance (size-dependent)250 mL: 27,000 x g / 500 mL: 13,500 x g / 1000 mL: 7,000 x g (validated with ≥80% fill)
SterilityNon-sterile standard; autoclavable 121°C × 20 min
Purity assuranceDNase-free, RNase-free, endotoxin-free
Rotor compatibilityBeckman Avanti / Thermo Sorvall / Eppendorf large-volume high-speed rotors
Application typeLarge-volume cell supernatant, protein precipitation, bacterial culture harvesting, bioprocessing bulk clarification
LimitationNot for ultracentrifugation (>100,000 x g); requires ≥80% fill for max RCF

Decision Table – Why Upgrade to Hawach High-Speed Bottles

ProblemSolution (Hawach Design)OutcomeImpact
Large-volume bottle deformation at high g-forceReinforced wall thickness + radial rib design on base; validated up to 27,000x g (250 mL), 13,500x g (500 mL), 7,000x g (1000 mL)Maintains round profile under rated RCF; no bucklingHigh (prevents rotor imbalance & sample loss)
Leakage from threaded cap under centrifugal forceDeep thread + silicone O-ring seal (optional upgrade available)Zero visible leakage during high-speed runsHigh (protects rotor and adjacent samples)
Sample residue on inner wall after decantingLow-retention inner surface (smooth, minimal binding)Higher recovery of proteins, antibodies, or cell-free supernatantsHigh (reduces waste of valuable biological fluids)
Poor batch consistency across large volume ordersISO 9001:2024 + lot traceability + ≤1% dimensional toleranceStable fit in rotors and reproducible pelletingMedium (essential for GMP/QC labs)
Incompatible with standard high-speed rotorsDimensions matched to Beckman, Sorvall, Thermo large-bucket systemsDirect drop-in or simple adapter compatibilityMedium (reduces need for new rotors)

Product Specification Overview

All bottles are supplied with leak-resistant screw caps (polypropylene with silicone liner). Sterile options available upon request (E-beam).

SKUVolumeMax RCFOuter Diameter (mm)Height (mm)PackagingCarton Qty
11361001250 mL27,000 x g61.8127.76 pcs/bag10 bags – 60 pcs
11361002500 mL13,500 x g69.51706 pcs/bag5 bags – 30 pcs
11361003500 mL13,500 x g741706 pcs/bag5 bags – 30 pcs
113610041000 mL7,000 x g981796 pcs/bag2 bags – 12 pcs
113610051000 mL7,000 x g97.51856 pcs/bag2 bags – 12 pcs

Note: 500 mL and 1000 mL variants are offered with different diameter/height to suit specific rotor buckets. Check compatibility table before ordering.

Rotor Compatibility Guidance

The following compatibility is based on common large-volume high-speed rotors. Free rotor verification available.

Rotor / Centrifuge Model250 mL (Ø61.8mm)500 mL (Ø69.5mm)500 mL (Ø74mm)1000 mL (Ø98/97.5mm)
Beckman Avanti J-LA / J-10 seriesDirect (with adapter)Direct or adapterCheck clearanceDirect (specific buckets)
Thermo Sorvall SLA-3000 / RC-12DirectDirectDirect (wide buckets)Direct (large buckets)
Eppendorf FA-45-6-30 (high-speed)Adapter requiredNot standardNoNo
Hettich / VWR general purposeYesYesYesCheck rotor manual

Engineered for Large-Volume High-Speed Performance

  • Thick-wall design with radial reinforcement– Prevents barrel distortion at elevated g- Validated to 27,000x g for 250 mL bottles, 13,500x g for 500 mL, and 7,000x g for 1000 mL.
  • Leak-resistant screw cap– Deep thread engagement and optional silicone liner maintain seal up to rated RCF even with volatile or detergent-containing solutions.
  • Smooth low-retention interior– Minimizes protein and cell debris adhesion. Improves recovery of clarified supernatants and reduces washing steps.
  • Chemical & thermal resistance– USP Class VI PP withstands common biological buffers, mild acids/bases, alcohols, and repeated autoclaving (121°C, 20 min, ≤5 cycles).
  • Precision dimensional control– Lot-to-lot diameter and height tolerance ≤1% ensures consistent fit in rotor buckets and adapters.

Operational Guidelines

Critical for maximum RCF: Fill volume must be ≥80% of nominal capacity (e.g., ≥200 mL for 250 mL bottle). Lower fill volumes increase risk of sidewall collapse or cap leakage under high g-force.

  • Recommended fill: 80-100% for high-speed runs. Leave small air gap for thermal expansion when autoclaving.
  • Autoclaving: 121°C, 20 minutes, up to 5 cycles. Inspect for cracking or deformation after repeated use.
  • Chemical compatibility: PBS, Tris, HEPES, sucrose, CsCl (<1.6 g/mL), ethanol (≤70%), isopropanol, mild detergents.
    Avoid: strong acids/bases (>1N), chlorinated solvents, phenol, chloroform, acetone.
  • Centrifuge balancing: Always use opposite bottles with equal fill weight. For swinging-bucket rotors, ensure caps are fully tightened but not over-

Performance Benchmark

Test protocol reference: ISO-like centrifugation condition (fixed-angle or swinging-bucket rotor, rated RCF per size, ≥80% fill, 25°C, 0.9% saline or PBS buffer) – internal validation for lab-grade benchmark definition.

MetricGeneric Economy PP BottlesHawach High-Speed PP Bottles
Wall deformation at rated RCFNoticeable bulging or oval shape (especially at 20,000x g for 250 mL)No visible distortion up to 27,000x g (250 mL) / 13,500x g (500 mL) / 7,000x g (1000 mL)
Leakage rate (filled, capped, spun)~3-5% under max load<1% (batch validated)
Protein recovery (BSA 1 mg/mL)82-86%≥92% (low-retention surface)
Autoclave cycles before degradation2-3 cycles≥5 cycles (reduced mechanical loss)
Dimensional consistency (OD)±2-3%≤1% (lot traceable)

Application Intelligence

Typical large-volume high-speed workflows (matching bottle RCF capabilities):

  • Harvesting bacterial or yeast cell pellets from 1-5 L cultures -250 mL / 500 mL bottles at 10,000-20,000x g
  • Clarification of cell culture supernatants prior to protein purification -500-1000 mL bottles up to 13,500x g / 7,000x g
  • Large-volume precipitation of nucleic acids or PEG-protein complexes -250-500 mL bottles up to 27,000x g or 13,500x g
  • Bulk separation of microalgae or fine particles -250-1000 mL bottles
  • Removal of cell debris from bioreactor harvests -1000 mL bottles at 7,000x g
  • Industrial QC sample preparation (food, environmental, pharmaceutical) -any size

Application-Based Selection Guide

ApplicationRecommended SizeTypical RCF RangeKey Bottle Feature
High-speed bacterial pellet (dense cultures)250 mL20,000-27,000 x gMaximum mechanical strength (27,000x g rated)
Mammalian cell supernatant clarification500 mL8,000-13,500 x gLow-retention surface
Protein precipitation (ammonium sulfate, PEG)250-500 mL12,000-15,000 x gChemical resistance, high RCF
Large-volume debris removal (bioprocessing)1000 mL5,000-7,000 x gAutoclavable, wide neck, 7,000x g validated

Procurement & Packaging

All bottles supplied with standard screw caps (PP). Sterile (E-beam) and bulk non-sterile options available upon request.

SKUVolumePackaging FormatBottles per Carton
11361001250 mL6/bag * 4 bags24
11361002500 mL (Ø69.5)6/bag * 2 bags12
11361003500 mL (Ø74)6/bag * 2 bags12
113610041000 mL (Ø98)6/bag * 3 bags18
113610051000 mL (Ø97.5)6/bag * 3 bags18

OEM & Bulk Supply Options

ServiceMOQ
Logo printing on bottle body20,000 pcs per size
Private label carton & bag500 cartons
Custom labelling (barcode, lot#)10,000 pcs
Annual fixed-price contract≥10,000 pcs/year (mix sizes)

Documentation available: COA, DNase/RNase-free certificate, endotoxin report, sterility validation (if sterile ordered), ISO 9001 compliance.

Frequently Asked Questions

Can 500 mL bottles be used at 27,000 x g?

No. The 500 mL bottles are rated for 13,500 ×g maximum. Use the 250 mL size for applications requiring higher RCF.

Can these bottles be used in swinging-bucket rotors?

Yes, most are designed for swinging-bucket or fixed-angle large-volume rotors. Always check bucket internal diameter vs bottle outer diameter. Contact us for rotor-specific advice.

How many times can I autoclave them?

Recommended ≤5 cycles at 121°C for 20 minutes. After each cycle, inspect for haze, cracks, or loss of rigidity. Discard if damaged.

Do you offer sample bottles for testing?

Yes. Free samples (up to 2 bottles per size) available for qualified labs. Request via the form below.

What is the difference between 11361002 and 11361003 (both 500 mL)?

Different outer diameters (69.5 mm vs 74 mm) to fit specific rotor families. 11361002 fits tighter buckets (e.g., Sorvall), 11361003 fits wider buckets (e.g., Beckman). Consult rotor manual or send your rotor model.

Request Samples & Bulk Quotation

Free evaluation samples (up to 2 bottles per SKU)
Rotor compatibility verification – send your centrifuge model & rotor type
Bulk pricing, OEM customization, and long-term supply agreements
Response within 24 hours

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top