+86-29-89284429

Cellulose Acetate Syringe Filters

Hawach Cellulose Acetate Syringe Filters have limited resistance to organic solutions. Cellulose Acetate Syringe Filters are an excellent choice for protein recovery applications due to its low protein binding rate.

Description

Description of Cellulose Acetate Syringe Filters

Cellulose Acetate Syringe Filters combine high flow rates and thermal stability with very low absorption characteristics, suitable for filtration of proteins and enzymes, sterilization of tissues, and culture media. Cellulose acetate membrane syringe filters have uniform pore size, no media shedding, thin texture, low resistance, fast filtration speed, and very little adsorption. 0.45 micron filter sterilization can be used to filter particles and bacteria of gas, oil, beverages, wine, etc., and can be used as a test for particles and bacteria.

In HPLC analysis, the particle size of the chromatographic column packing is small and it is easy to be blocked by impurity particles. Therefore, samples and solvents need to be filtered in advance to remove particulate contaminants and protect the instrument.

Ion chromatography, which is commonly used in environmental analysis, also requires that no inorganic contaminants be introduced in sample pretreatment. Syringe filters can be used in HPLC analysis and IC analysis. Filtering sample solutions is an important step in the sample pretreatment process.

Advantage of Cellulose Acetate Membrane Syringe Filters

Hydrophilic CA syringe filters
Low protein binding
High throughput
Excellent strength and stability
Option standard 1um pre-filter providing increased sample handling capacity

Applications of 0.22, 0.45 Micron Filter Sterilization

HPLC sample preparation
Biological sample preparation
Protein and enzyme filtration
Cell culture
Clarification of aqueous and alcohol solutions
Filtration of aqueous-based solutions or biologic samples

Chemical Compatibility

Incompatible with Organic solvents: Acids, NaOH, dichloromethane, chloroform, ketones, DMSO, THF

Technical Data

Filter MediaCellulose Acetate
Diameter4mm13mm25mm33mm50mm
HousingMedical PP
Pore Size0.1μm, 0.22μm, 0.45μm, 0.8μm, 1.0μm, 3.0μm, 5.0μm
Filtration Area0.2cm21.3cm24.9cm28.5cm219.8cm2
Maximum Pressure5.2bar
Process Volume2mL10mL100mL200mL5000mL
Pre-filter1μm GF or PP
Hold-up Volume< 10μL< 50μL< 100μL< 200μL< 350μL
InletFemale Luer LockStepped barb
OutletMale Luer slipStepped barb
Operate temperature60°C

Instruction Drawing

syringe-filters-analysis-chart-800x281 (2)

Ordering Information

Item CodeDiameter(mm)Pore Size(μm)Pre-filterQuantity/pk
SLCA0410N40.1No100pcs
SLCA0422N0.22
SLCA0445N0.45
SLCA0480N0.8
SLCA04100N1
SLCA04300N3
SLCA04500N5
SLCA1310N130.1No100pcs
SLCA1322N0.22
SLCA1345N0.45
SLCA1380N0.8
SLCA13100N1
SLCA13300N3
SLCA13500N5
SLCA1310NP0.1PP
SLCA1322NP0.22
SLCA1345NP0.45
SLCA1380NP0.8
SLCA13100NP1
SLCA13300NP3
SLCA13500NP5
SLCA1310NG0.1GF
SLCA1322NG0.22
SLCA1345NG0.45
SLCA1380NG0.8
SLCA13100NG1
SLCA13300NG3
SLCA13500NG5
SLCA2510N250.1No100pcs
SLCA2522N0.22
SLCA2545N0.45
SLCA2580N0.8
SLCA25100N1
SLCA25300N3
SLCA25500N5
SLCA2510NP0.1PP
SLCA2522NP0.22
SLCA2545NP0.45
SLCA2580NP0.8
SLCA25100NP1
SLCA25300NP3
SLCA25500NP5
SLCA2510NG0.1GF
SLCA2522NG0.22
SLCA2545NG0.45
SLCA2580NG0.8
SLCA25100NG1
SLCA25300NG3
SLCA25500NG5
SLCA3310N330.1No50pcs
SLCA3322N0.22
SLCA3345N0.45
SLCA3380N0.8
SLCA33100N1
SLCA33300N3
SLCA33500N5
SLCA3310NP0.1PP
SLCA3322NP0.22
SLCA3345NP0.45
SLCA3380NP0.8
SLCA33100NP1
SLCA33300NP3
SLCA33500NP5
SLCA3310NG0.1GF
SLCA3322NG0.22
SLCA3345NG0.45
SLCA3380NG0.8
SLCA33100NG1
SLCA33300NG3
SLCA33500NG5
SLCA5010N500.1No25pcs
SLCA5022N0.22
SLCA5045N0.45
SLCA5080N0.8
SLCA50100N1
SLCA50300N3
SLCA50500N5
SLCA5010NP0.1PP
SLCA5022NP0.22
SLCA5045NP0.45
SLCA5080NP0.8
SLCA50100NP1
SLCA50300NP3
SLCA50500NP5
SLCA5010NG0.1GF
SLCA5022NG0.22
SLCA5045NG0.45
SLCA5080NG0.8
SLCA50100NG1
SLCA50300NG3
SLCA50500NG5
CONTACT FORM
Enter your email address to receive all news, updates on new arrivals,
special offers and other discount information.