+86-29-89284429

PP Syringe Filters

Filter Media: Hydrophobic PP
Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.1μm, 0.22μm, 0.45μm, 0.65μm, 0.8μm, 1μm, 3μm, 5μm, 10μm

Availability: In Stock

Description

Cost-Effective Hydrophobic Filtration for General Laboratory Use

Hawach PP syringe filters are designed for broad laboratory filtration applications, offering excellent chemical resistance, low protein binding, and high dirt-holding capacity.

Constructed from pure polypropylene (PP), these filters are:

  • Slightly hydrophobic
  • Highly chemically resistant
  • Suitable for both aqueous and organic samples
  • Ideal for pre-filtration and general clarification

Widely used in HPLC, ion chromatography, and routine lab workflows

Recommended Configuration

PP Syringe Filters (0.22 µm / 0.45 µm)

  • Cost-effective for routine filtration
  • Low protein adsorption → suitable for biomolecules
  • High porosity → strong dirt holding capacity
  • Compatible with acids, bases, and many solvents
  • Available in sterile and non-sterile formats

Best for pre-filtration, sample cleanup, and general lab use

Instruction Drawing

syringe-filters-analysis-chart-800x281 (2)

Quick Selection Guide

ApplicationRecommended TypePore Size
HPLC sample prepStandard PP0.22 µm
Ion chromatographyStandard PP0.22 µm
General clarificationStandard PP0.45 µm
Sterile workflowsSterile PP0.22 µm
High particulate samplesPP + prefilter0.65–5.0 µm

Product Series Overview

1. Standard PP Syringe Filters

Designed for routine laboratory filtration

  • Broad chemical compatibility
  • High flow rate and low resistance
  • Suitable for aqueous and organic solutions
  • Cost-effective for large-volume usage

2. Sterile PP Syringe Filters

Designed for aseptic and analytical applications

  • Sterile packaging for contamination control
  • High consistency for HPLC analysis
  • Low extractables and stable performance
  • Suitable for pharmaceutical and biological workflows

Applications

PP syringe filters are widely used in:

  • HPLC / GC sample preparation
  • Ion chromatography (IC)
  • Environmental testing
  • Pharmaceutical analysis
  • Heavy metal digestion samples
  • General laboratory filtration

Why Choose PP Membrane?

Polypropylene membranes offer a unique combination of chemical resistance and affordability.

Key advantages:

  • Broad chemical compatibility (acids, bases, solvents)
  • Low protein binding
  • High dirt holding capacity
  • Hydrophobic nature → suitable for gas & solvent filtration
  • High pressure resistance

Limitations:

  • Not ideal for highly aromatic or chlorinated solvents

PP vs Other Membranes

MembraneBest For
PPGeneral + prefiltration
PTFEStrong solvents, gases
PVDFLow protein + solvents
PESBiological aqueous

Technical Specifications

ParameterSpecification
MembranePolypropylene (PP), hydrophobic
Pore Size0.1 – 10 µm
Diameter4 / 13 / 25 / 33 / 50 mm
HousingMedical-grade PP
Max Pressure~5.2 bar
Filtration AreaUp to 19.8 cm²
Protein BindingLow

Ordering Information

Standard PP Filters (Non-sterile)

Below are the most commonly ordered configurations. For custom pore sizes, diameters, or OEM requirements, please contact us.

Item CodePore Size(µm)Diameter(mm)SterilePre-filterQuantity/pk
110841010.224NoNo100
110841020.454NoNo100
110881030.2213NoPP100
110881040.4513NoPP100
110881050.2225NoGF100
110881060.4525NoGF100
110881130.2233NoNo50
110881140.4533NoPP50
110881180.2250NoGF25
110881190.4550NoGF25

Sterile PP Filters

Cat#Pore Size(µm)Diameter(mm)SterilePackage(pcs/pk)
110843010.224Gamma sterile100
110843020.454Gamma sterile100
1108430314Gamma sterile100
1108430454Gamma sterile100
110883030.2213Gamma sterile100
110883040.4513Gamma sterile100
11088307113Gamma sterile100
11088308313Gamma sterile100
11088309513Gamma sterile100
110883050.2225Gamma sterile100
110883060.4525Gamma sterile100
11088310125Gamma sterile100
11088311325Gamma sterile100
11088312525Gamma sterile100
110883130.2233Gamma sterile50
110883140.4533Gamma sterile50
11088315133Gamma sterile50
11088316333Gamma sterile50
11088317533Gamma sterile50
110883180.2250Gamma sterile25
110883190.4550Gamma sterile25
11088320150Gamma sterile25
11088321350Gamma sterile25
11088322550Gamma sterile25

 

Why Choose Hawach PP Syringe Filters?

  • ISO 9001 certified
  • Medical-grade polypropylene
  • Cleanroom production available
  • Stable batch-to-batch consistency
  • OEM / private label support
  • Competitive factory pricing

Bulk Order & OEM Supply

  • Bulk discounts
  • Custom branding & packaging
  • Fast global shipping
  • Technical support

Request quotation within 24 hours

FAQ

What are PP syringe filters used for?

Used for general filtration, HPLC sample prep, and ion chromatography.

Are PP syringe filters hydrophobic?

Yes, PP membranes are naturally hydrophobic, suitable for gas and solvent filtration.

Can PP filters be used for proteins?

Yes, they have low protein binding, but not as low as PVDF or PES.

Related: PVDF syringe filters, PES syringe filter

What is the advantage of PP filters?

They are cost-effective, chemically resistant, and versatile.

When should I use sterile PP filters?

For pharmaceutical, biological, or contamination-sensitive applications.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top