Hawach HPLC Guard Columns are designed to protect analytical HPLC columns from contamination caused by sample matrices, particulate matter, strongly retained compounds and chemical impurities. Installed between the injector and analytical column, a guard column acts as a protective pre-column to extend analytical column lifetime while maintaining reliable chromatographic performance.

Our HPLC Guard Column Set includes a high-efficiency guard cartridge, analytical guard column holder, PEEK tubing and fittings, providing a complete installation solution for modern HPLC and UHPLC systems.

Available stationary phases: C18, C8, Phenyl, C4, C30, CN, NH2, HILIC Amide, Silica, Diol, SAX, SCX, PFP, Polar-RP, Amino Acid, PAH, C1, Sugar-H and other specialty phases.
Guard Column and Spare Parts

Why Use an HPLC Guard Column?

BenefitDescription
Protect Analytical ColumnsCaptures contaminants before they reach the main column, preventing irreversible adsorption and premature failure
Extend Column LifetimeReplacing guard cartridges is more economical than replacing expensive analytical columns
Maintain PerformanceCompatible stationary phases ensure similar selectivity, minimizing retention shifts and peak distortion
Reduce Operating CostSignificantly lowers long-term chromatography costs

Guard Column Set Structure

ComponentDescription
Guard CartridgePacked stationary phase cartridge for contaminant removal
Guard Column HolderAnalytical guard column holder
PEEK Tube1/16″ PEEK connection tubing
PEEK FittingsHigh-pressure connection fittings

Technical Specifications

ParameterSpecification
Product TypeHPLC Guard Column Set
Stationary PhasesC18, C8, Phenyl, C4, C30, CN, NH2, HILIC, Silica, Diol, Ion Exchange, Specialty
Particle Sizes3μm, 5μm, 10μm (1.8μm for C18-Universal)
Pore Sizes120Å, 300Å
Cartridge Length10mm (5mm for C18-Universal)
Internal Diameter2.1mm, 4.6mm
ConnectionPEEK tubing and fittings
ApplicationHPLC / UHPLC column protection

Available Stationary Phases – Quick Reference

PhaseChemistryBest For
C18-UniversalOctadecyl (C18)General reversed-phase, broad compatibility
C18-Low pHC18 (acid-stable)Low pH mobile phase conditions
C18-AqueousC18 (aqueous-stable)Highly aqueous mobile phases
C8-UniversalOctyl (C8)Pharmaceuticals, peptides, moderate retention
C8-FluorineC8 + fluorinated modifierHalogenated compounds
C8-Low pHC8 (acid-stable)Low pH reversed-phase
PhenylPhenyl bondedAromatic compounds, π-π interactions
Phenyl-EtherPhenyl + etherAlternative aromatic selectivity
C4Butyl (C4)Proteins, peptides, large biomolecules
C30Triacontyl (C30)Carotenoids, lipids, isomers
CNCyanoMedium polarity, reversed/normal phase
NH₂AminoCarbohydrates, sugars, polar compounds
HILIC AmideAmideHighly polar compounds, HILIC applications
SiO₂Bare silicaNormal-phase chromatography
DiolDiolPolar compounds, biomolecules
SCXStrong Cation ExchangeBasic compounds, ion exchange
SAXStrong Anion ExchangeNucleotides, organic acids
PFPPentafluorophenylHalogenated, polar aromatics
Polar-RPPolar embeddedAlternative selectivity for polar analytes
Amino AcidSpecialtyAmino acid analysis
PAHPAH selectivePolycyclic aromatic hydrocarbons
C1Methyl (C1)Low hydrophobicity, alternative selectivity
Sugar-HSugar specificCarbohydrate and sugar analysis

Ordering Information – Representative SKUs

C18-Universal Guard Column Set

Cat#Description
13041053C18-Universal, 1.8μm, 120Å, 2.1*5mm Set
13041001C18-Universal, 3μm, 120Å, 4.6*10mm Set
13041003C18-Universal, 5μm, 120Å, 4.6*10mm Set
13041007C18-Universal, 10μm, 120Å, 4.6*10mm Set

C18-Low pH / C18-Aqueous Guard Column Set

Cat#Description
13041051C18-Low pH, 3μm, 120Å, 4.6*10mm Set
13041037C18-Low pH, 5μm, 120Å, 4.6*10mm Set
13041043C18-Aqueous, 3μm, 120Å, 4.6*10mm Set
13041042C18-Aqueous, 5μm, 120Å, 4.6*10mm Set

C8 Guard Column Set

Cat#Description
13041002C8-Universal, 3μm, 120Å, 4.6*10mm Set
13041004C8-Universal, 5μm, 120Å, 4.6*10mm Set
13041032C8-Fluorine, 5μm, 120Å, 4.6*10mm Set
13041034C8-Low pH, 3μm, 120Å, 4.6*10mm Set

Phenyl / Phenyl-Ether Guard Column Set

Cat#Description
13041022Phenyl, 3μm, 120Å, 4.6*10mm Set
13041006Phenyl, 5μm, 120Å, 4.6*10mm Set
13041018Phenyl-Ether, 5μm, 120Å, 4.6*10mm Set

C4 Guard Column Set

Cat#Description
13041071C4, 3μm, 120Å, 4.6*10mm Set
13041031C4, 5μm, 120Å, 4.6*10mm Set

C30 Guard Column Set

Cat#Description
13041073C30, 3μm, 120Å, 4.6*10mm Set
13041024C30, 5μm, 120Å, 4.6*10mm Set

CN / NH₂ / Diol / SiO₂ Guard Column Set

Cat#Description
13041005CN, 5μm, 120Å, 4.6*10mm Set
13041027NH₂, 5μm, 120Å, 4.6*10mm Set
13041012Diol, 5μm, 120Å, 4.6*10mm Set
13041015SiO₂, 5μm, 120Å, 4.6*10mm Set

SCX / SAX / PFP / Polar-RP Guard Column Set

Cat#Description
13041009SCX, 5μm, 120Å, 4.6*10mm Set
13041010SAX, 5μm, 120Å, 4.6*10mm Set
13041019PFP, 5μm, 120Å, 4.6*10mm Set
13041038Polar-RP, 5μm, 120Å, 4.6*10mm Set

Specialty Guard Column Set

Cat#Description
13041047Amino Acid, 5μm, 120Å, 4.6*10mm Set
13041011HILIC Amide, 5μm, 120Å, 4.6*10mm Set
13041041PAH, 5μm, 120Å, 4.6*10mm Set
13041029C1, 5μm, 120Å, 4.6*10mm Set
13041050Sugar-H, 5μm, 4.6*10mm Set

Full SKU list available – including 2.1mm ID, 300Å pore size, and all particle size options. Contact info@hawach.com for complete catalog.

Or download the PDF below.
Download PDF Datasheet

How to Select an HPLC Guard Column

Match Stationary Phase

Analytical ColumnRecommended Guard Column
C18 ColumnC18-Universal / C18-Low pH / C18-Aqueous
C8 ColumnC8-Universal / C8-Low pH
Phenyl ColumnPhenyl Guard Column
C4 ColumnC4 Guard Column
HILIC ColumnHILIC Amide Guard Column
NH₂ ColumnNH₂ Guard Column

Match Internal Diameter

  • 1mm ID analytical column –2.1*10mm guard cartridge
  • 6mm ID analytical column –4.6*10mm guard cartridge

Match Particle Size

Analytical ColumnGuard Column
1.7-2μm UHPLC1.8-3μm Guard
3μm HPLC3μm Guard
5μm HPLC5μm Guard

Installation Guide

Installation Sequence:

HPLC Pump — Injector — HPLC Guard Column — Analytical HPLC Column — Detector

Installation Steps:

  • Select compatible guard column (match chemistry, ID, particle size)
  • Install guard holder using supplied PEEK tubing and fittings
  • Confirm flow direction (marked on cartridge)
  • Condition with initial mobile phase before sample injection

Maintenance Recommendations

Replace guard cartridge regularly when you observe:

  • Increased system pressure
  • Retention time drift
  • Reduced peak resolution
  • Unexpected peak shape changes

Guard Column vs Analytical Column

FeatureGuard ColumnAnalytical Column
Main FunctionColumn protectionCompound separation
PositionBefore analytical columnMain separation component
LengthShort (5-10mm)Longer (50-300mm)
ReplacementRegular (economical)Less frequent (expensive)
CostLowerHigher

FAQs

What is an HPLC Guard Column?

A short protective cartridge installed before an analytical HPLC column to remove contaminants and protect the analytical column from sample matrix damage.

Does a guard column affect HPLC separation?

A properly matched guard column should have minimal impact on separation performance when the stationary phase matches the analytical column.

How often should a guard column be replaced?

Replacement frequency depends on sample type and contamination level. Replace when pressure increases or chromatographic performance decreases.

Should the guard column chemistry match the analytical column?

Yes. For best performance, use the same stationary phase chemistry as the analytical column.

Can guard columns be used for UHPLC?

Yes. Guard columns with smaller particle sizes (1.8μm and 3μm) are compatible with UHPLC systems.