Filter Media: Glass Fiber
Housing: Medical PP
Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.45μm, 1.0μm, 1.6μm
Availability: In Stock
Filter Media: Glass Fiber
Housing: Medical PP
Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.45μm, 1.0μm, 1.6μm
Availability: In Stock
Glass fiber syringe filters are depth pre-filtration membranes designed for high-flow sample clarification and particulate removal.
Hawach glass fiber syringe filters (GF) are high-flow, depth filtration membranes designed for pre-filtration, particulate removal, and clarification of highly loaded or viscous samples. Made from 100% borosilicate glass fiber, GF filters provide extremely high flow rate, strong dirt-holding capacity, excellent compatibility with aqueous & organic solutions, and reliable pre-filtration before fine membrane filtration.
Ideal for HPLC sample prep, biological fluids, fermentation broth, and dirty samples.
Best used as first-stage pre-filtration before fine filtration (CA / PES / PVDF / PTFE)
Instruction Drawing

| Use Case | Recommended Series | Pore Size |
| Pre-filtration before HPLC / membrane filters | Standard GF | 1.0 – 1.6 µm |
| Fermentation broth / biological fluids | Sterile GF | 0.45 µm |
| Viscous or particle-rich samples | Standard GF | 1.0 – 1.6 µm |
| High particulate samples (general clarification) | Standard GF | 0.45 µm |
| General lab clarification | Standard GF | 0.45 – 1.0 µm |
Glass fiber syringe filters are widely used in:
| Series | Sterility | Positioning | Main Function |
| Standard GF | Non-sterile | Routine lab use | Pre-filtration & clarification |
| Sterile GF | Gamma sterile | Bio/pharma grade | Aseptic sample pre-filtration |
| Parameter | Specification |
| Membrane Material | 100% borosilicate glass fiber (GF) |
| Filtration Type | Depth filtration |
| Pore Sizes | 0.45 / 1.0 / 1.6 µm |
| Diameters | 4 mm, 13 mm, 25 mm, 33 mm, 50 mm |
| Housing Material | Medical-grade polypropylene (PP) |
| Max Operating Pressure | ≤ 5.2 bar (approx. 75 psi) |
| Temperature Range | Up to 60°C |
| Sterility (Sterile Series) | Gamma irradiation (SAL 10⁻⁶) |
| Chemical Compatibility | Aqueous & most organic solvents |
| Typical Flow Rate | > 100 mL/min at 1 bar (25 mm, 0.45 µm) |
| Item Code | Pore Size(µm) | Diameter(mm) | Sterile | Quantity/pk |
| 11078301 | 0.7 | 13 | Gamma sterile | 100 |
| 11078302 | 1 | 13 | Gamma sterile | 100 |
| 11078303 | 0.7 | 25 | Gamma sterile | 100 |
| 11078304 | 1 | 25 | Gamma sterile | 100 |
| 11078307 | 0.7 | 33 | Gamma sterile | 50 |
| 11078308 | 1 | 33 | Gamma sterile | 50 |
| 11078310 | 0.7 | 50 | Gamma sterile | 25 |
| 11078311 | 1 | 50 | Gamma sterile | 25 |
| Item Code | Pore Size(µm) | Diameter(mm) | Sterile | Quantity/pk |
| 11078101 | 0.7 | 13 | NO | 100 |
| 11078114 | 1.2 | 13 | NO | 100 |
| 11078103 | 0.7 | 25 | NO | 100 |
| 11078115 | 1.2 | 25 | NO | 100 |
| 11078112 | 2.7 | 25 | NO | 100 |
| 11078107 | 0.7 | 33 | NO | 50 |
| 11078108 | 1 | 33 | NO | 50 |
| 11078109 | 1.6 | 33 | NO | 50 |
Custom options: Pore sizes 1.0 µm, 1.6 µm, and other diameters available upon request. Contact sales for OEM and private label.
| Membrane | Strength | Best Use | Limitation |
| Glass Fiber (GF) | High flow + high dirt capacity | Pre-filtration, viscous, dirty samples | Not for final sterilization; may shed fibers |
| CA | Low protein binding | Biological aqueous filtration | Not for organic solvents |
| PES | Ultra-low protein binding | Proteins, enzymes | Not for solvents |
| PTFE | Chemical resistance | Organic solvents, gases | Requires pre-wetting for water |
For biological sample filtration – CA Syringe Filters
For protein-sensitive filtration – PES Syringe Filters
For solvent filtration – PTFE Syringe Filters
| Feature | Benefit |
| High flow depth filtration | Fast processing of viscous or particle-loaded samples |
| Excellent clog resistance | Longer filter life, less clogging |
| Stable borosilicate fiber quality | Consistent performance batch to batch |
| Low extractables | Clean HPLC baselines |
| Sterile option available | Ready for aseptic pre-filtration |
| ISO certified manufacturing | Reliable quality and traceability |
It is mainly used for pre-filtration and particulate removal in high-load or viscous samples before final filtration through a membrane filter (CA, PES, PVDF, PTFE).
No. GF is a depth pre-filter. For sterile filtration, always follow with a 0.22 µm membrane filter (CA, PES, or PVDF).
Glass fiber is hydrophilic and inert, compatible with both aqueous and most organic solvents.
Because it prevents clogging and dramatically increases the lifespan and throughput of final membrane filters – especially for dirty, turbid, or high-viscosity samples.
Yes, for clarification of particulate-loaded samples, but not for sterilization or particle-free final filtration.
High-quality GF filters (Hawach) minimize shedding, but for applications where absolute particle removal is required, always use a final membrane filter downstream.
Hawach glass fiber syringe filters are available in multiple pore sizes (0.45, 1.0, 1.6 µm), diameters (4–50 mm), and sterility configurations. We support:

The quality has a guarantee
Fast & safe shipping worldwide