+86-29-89284429

Roller Mixer

5 or 7 rollers
20-110 rpm adjustable speed
Digital timer model (10-999 min) available
Simultaneous rolling + rocking motion
Low noise DC motor
12 W energy-efficient operation
Compact benchtop design

Availability: In Stock

Description

The Hawach roller mixer is a laboratory benchtop mixing instrument designed for gentle rolling and rocking motion of blood tubes, viscous liquids, and liquid-solid suspensions. It is widely used in clinical laboratories, blood banks, pharmaceutical R&D, and biotechnology workflows for consistent and non-destructive sample mixing.

Quick Selection Guide- Which Roller Mixer Fits Your Workflow?

ApplicationRecommended Roller Mixer ModelKey Specifications
Blood tube mixing & anticoagulation (clinical labs)18102006 (7-roller analog)20-110 rpm, 22 mm amplitude, gentle rolling + rocking
Time-controlled mixing, unattended operation18102008 (7-roller digital timer)20-110 rpm, timer 10-999 min, same rolling + rocking action
Higher throughput (multiple tubes / bottles) – any application7-roller models (18102006 / 18102008)Accommodates more samples per run
Smaller labs, lower throughput, basic mixing5-roller analog (18102005)20-110 rpm, compact footprint, economical

Not sure which roller mixer suits your protocol? Email info@hawach.com with your sample type and daily throughput – we will recommend the right model.

Direct Replacement for Thermo Scientific, Bio-Rad & Labquake Roller Mixers

Hawach roller mixers deliver equivalent gentle mixing performance for blood samples, viscous liquids, and liquid-solid suspensions at a significantly lower procurement cost. Use the same protocols – no workflow changes required. All Hawach roller mixers are compatible with standard blood collection tubes (Vacutainer®), centrifuge tubes, culture bottles, and various laboratory containers.

Competitor ModelHawach Roller Mixer EquivalentKey SpecificationsCost Advantage
Thermo Scientific Bottle/Tube Roller (digital)18102008 (7-roller digital timer)20-110 rpm, timer 10-999 min, 12 W40-50% lower
Bio-Rad Tube Roller18102006 (7-roller analog)20-110 rpm, 22 mm amplitude, quiet DC motor35-45% lower
Labquake Tube Roller/Rotator18102007 (5-roller digital timer)Timer control, gentle rolling + rocking30-40% lower

Why Laboratories Replace Thermo Scientific Roller Mixers with Hawach

  • Equivalent rolling + rocking motion– Same gentle 360° rotation and end-to-end tilt that preserves blood cell integrity and prevents coagulation.
  • Same blood tube compatibility– Works with all standard blood collection tubes (Vacutainer®), centrifuge tubes (5-50 mL), and culture bottles.
  • Similar digital timer workflow– Digital models (18102007, 18102008) offer programmable timing (10-999 min) for unattended operation, identical to premium brands.
  • Lower procurement cost– 30-50% less than Thermo Scientific, Bio-Rad, or Labquake roller mixers without compromising performance.
  • Faster OEM delivery– Standard models in stock; custom orders delivered within 4-6 weeks.
  • Easier distributor pricing– Volume discounts and long-term supply agreements available for OEM partners and distributors.
  • No protocol revalidation required– Use the same tube dimensions, same speed range, same mixing action – validated workflows transfer directly.

Recommended Roller Mixer by Application – Which Model Should You Choose?

ApplicationRecommended Roller Mixer ModelWhy This Model
Blood anticoagulation / routine blood tube mixing (clinical labs)18102006 (7-roller analog)7 rollers handle higher throughput; analog control allows quick speed adjustment during daily use
Time-controlled, repeatable mixing protocols (e.g., overnight, batch processing)18102008 (7-roller digital timer)Programmable timer ensures consistent run times for standardized operations
Viscous liquid mixing (glycerol, sera, cell suspensions)18102008 (7-roller digital timer)Higher speed range (60-110 rpm) and long-duration timing fully mix viscous liquids
Cell suspension mixing & immunoprecipitation (gentle, low shear)18102007 (5-roller digital timer)5 rollers are sufficient for smaller sample loads; timer allows overnight rotation without aeration
Continuous low-shear mixing (cold room / incubator environments)18102005 (5-roller analog)Low power consumption (12 W), simple analog control, reliable for long-term uninterrupted runs

What Is a Roller Mixer?

A roller mixer is a laboratory device that uses multiple motor-driven rollers to simultaneously rotate and gently rock tubes, bottles, or flasks. The unique combination of rolling motion and end-to-end tilt creates a gentle yet highly efficient mixing action, ideal for samples that must not be aerated or subjected to shear stress. A laboratory roller mixer is particularly valuable for blood tube mixing (preventing coagulation), viscous liquids, and liquid-solid suspensions.

Unlike rotators (which tumble samples more vigorously) or vortex mixers (high shear), a roller mixer for blood samples preserves sample integrity while ensuring thorough, homogeneous mixing. This makes the tube roller mixer the instrument of choice for clinical laboratories, blood banks, molecular biology, and pharmaceutical QC facilities.

Core Specifications of Hawach Roller Mixers

ParameterDetails
Number of rollers5 or 7
Speed range20 – 110 rpm (continuously adjustable)
Motion typeSimultaneous rolling + rocking (end-to-end tilt) – 360° gentle mixing
Amplitude22 mm
Timer (digital models)10 – 999 minutes, programmable
Motor typeEfficient DC motor, low noise, maintenance-free
Power consumption12 W
Tube / bottle compatibilityBlood collection tubes (all sizes), centrifuge tubes (5-50 mL), culture bottles, roller bottles, various laboratory containers
Operating environmentSuitable for cold rooms (4°C) and incubators (up to 60°C) on request

Typical Applications of Roller Mixers

  • Blood sample mixing & anticoagulation– A roller mixer for blood samples keeps anticoagulants evenly mixed in blood collection tubes without damaging blood cells, essential for hematology and coagulation studies.
  • Preventing blood clotting– Continuous gentle rolling and rocking motion maintains blood samples in a mixed state, preventing fibrin formation.
  • Viscous liquid & liquid-solid suspension mixing– Ideal for samples that are difficult to mix by manual inversion or vortexing (e.g., glycerol solutions, bacterial suspensions).
  • Cell culture & reagent preparation– Gently mixing cell suspensions, culture media, and biochemical reagents without introducing air bubbles.
  • Immunoprecipitation & protein workflows– End-over-end mixing of antibody-bead suspensions for protein pull-down assays.
  • Clinical diagnostics– Homogenizing urine, serum, or plasma samples before analysis.
  • Defrosting samples– Gentle rolling action aids uniform thawing of frozen samples without local overheating.

Why Laboratories Choose Hawach Roller Mixers Instead of Generic Brands

  • Genuine 360° rolling + rocking motion– Simultaneous rotation and end-to-end tilt ensures thorough mixing of blood collection tubes, viscous liquids, and liquid-solid suspensions without aeration.
  • Adjustable speed (20-110 rpm)– Fine-tune mixing intensity for different sample types; slower speeds for delicate blood cells, higher speeds for viscous solutions.
  • Digital timer models (10-999 min)– Programmable timing allows unattended operation and consistent, repeatable mixing protocols – ideal for standardized clinical workflows.
  • Quiet, low-vibration DC motor– Maintenance-free operation with minimal noise, comfortable for open-bench laboratories.
  • Energy-efficient 12 W power consumption– Low operating cost, suitable for continuous use in blood banks and QC labs.
  • 5 or 7 rollers– Choose roller count based on throughput; 5-roller models for smaller labs, 7-roller models for higher sample volume.
  • Compact footprint– Saves valuable bench space while accommodating multiple tubes or bottles simultaneously.
  • Cold room & incubator compatible– Stable operation in temperature-controlled environments (4°C to 60°C).
  • Full OEM support– Custom branding, packaging, and private label services for distributors and volume buyers.

Roller Mixer vs Rotator vs Rocker – Choosing the Right Mixer for Your Lab

FeatureRoller Mixer (Hawach)Rotator (End-over-end)Rocker (Platform)
Motion typeRolling + gentle rocking360° end-over-end rotationSide-to-side tilting
Mixing intensityGentle, low shear, no aerationModerate to vigorousGentle, wave-like
Best forBlood tubes, viscous liquids, cell suspensions, preventing coagulationBlood tube mixing (more vigorous), membrane washingBlotting, gentle resuspension, staining
Aeration riskVery low (prevents bubble formation)LowLow
Sample typesBlood collection tubes, centrifuge tubes, culture bottles, roller bottlesSealed tubes, microcentrifuge tubesBlotting membranes, staining trays

Ordering Information – Roller Mixer Models

Cat#DescriptionRollersSpeed (rpm)TimerPowerAmplitudePackaging
18102005Standard Roller Mixer520-110No (analog)12 W22 mm1 set/carton
18102006Standard Roller Mixer720-110No (analog)12 W22 mm1 set/carton
18102007Digital Timer Roller Mixer520-11010-999 min12 W22 mm1 set/carton
18102008Digital Timer Roller Mixer720-11010-999 min12 W22 mm1 set/carton

All models include: DC motor, continuously adjustable speed control, energy-efficient 12 W operation. Digital timer models include programmable timing for unattended runs. Custom configurations (roller count, timer, voltage) available for OEM volume orders.

Quality & Compliance

  • CE marked, RoHS compliant
  • Factory-tested for speed accuracy, motion stability, and load capacity
  • Full lot traceability and COA available upon request

Industries Served

  • Clinical & hospital laboratories (blood sample mixing, coagulation prevention)
  • Blood banks & blood centres (anticoagulant mixing in blood collection tubes)
  • Biotechnology & pharmaceutical R&D (cell culture, protein workflows)
  • Molecular biology laboratories (gentle mixing of viscous reagents and suspensions)
  • University research labs & teaching facilities
  • Food safety & environmental testing (mixing liquid-solid suspensions)

Frequently Asked Questions

Can Hawach roller mixers replace Thermo Scientific or Labquake models?

Yes. Hawach roller mixers deliver equivalent gentle mixing performance for blood samples, viscous liquids, and liquid-solid suspensions. Use the same tubes, protocols, and workflow – no method revalidation required. Digital timer models provide the same programmable timing as premium brands at a significantly lower cost.

What speed should I use for blood sample mixing?

For routine blood tube mixing to prevent clotting, 20-30 rpm is sufficient. For viscous samples, increase speed up to 110 rpm. The adjustable speed control allows fine-tuning for optimal mixing intensity without damaging blood cells.

Can I use the roller mixer in a cold room or incubator?

Yes. Hawach roller mixers operate reliably in cold rooms (4°C) and incubators (up to 60°C). Confirm environmental conditions with our technical team for specific applications.

What is the difference between a roller mixer and a rotator?

A roller mixer provides gentle rolling + rocking motion, ideal for blood tubes, viscous liquids, and preventing coagulation. A rotator tumbles tubes end-over-end more vigorously, suitable for membrane washing or samples requiring more aggressive mixing. For blood sample integrity, roller mixers are preferred.

Are the rollers autoclavable?

Rollers are resistant to laboratory disinfectants but are not designed for autoclaving. Surface cleaning with 70% ethanol or mild detergents is recommended between uses.

What is the power consumption of these roller mixers?

12 W – extremely energy-efficient, suitable for continuous use in busy clinical labs and blood banks.

ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top