320–1000 nm Wavelength Range
4 nm / 2 nm / 1.7 nm Bandwidth
Single-Beam
High-Performance 1200 L/mm Grating
Optional PC Software & Scanning
Availability: In Stock
320–1000 nm Wavelength Range
4 nm / 2 nm / 1.7 nm Bandwidth
Single-Beam
High-Performance 1200 L/mm Grating
Optional PC Software & Scanning
Availability: In Stock
Visible spectrophotometers are essential analytical devices that test the absorbance and transmittance of visible light (320-1000 nm) through liquid samples. They are widely used for colored substance quantification and colorimetric testing, ideal for routine quality control across multiple industries.
Different from UV-Vis spectrophotometers, visible-only models are a cost-effective choice for labs with no UV wavelength testing requirements. Hawach offers a full lineup of visible spectrophotometers, covering entry-level teaching models, mid-range routine testing equipment, and advanced PC-controlled devices with scanning and kinetic testing functions.
All units adopt professional Czerny-Turner (C-T) monochromators and 1200 lines/mm diffraction gratings, delivering low stray light, high optical resolution and stable photometric linearity. The spacious sample chamber supports cuvettes up to 100 mm pathlength, enabling ultra-low concentration detection for water quality monitoring, sugar refining and semiconductor testing.
Note: Visible spectrophotometers only support visible light sample analysis. For UV-dependent testing (nucleic acids, proteins, UV-active pharmaceutical ingredients), a UV-Vis spectrophotometer is required.
Entry-Level (721/722/722S/7230G): Manual wavelength adjustment, suitable for teaching experiments and basic routine QC. 7230G includes a standard dedicated printer for direct data documentation.
Mid-Range Automatic (723/723PC): Automatic wavelength positioning with higher accuracy; 723PC adds PC software, spectral scanning and kinetic testing functions for in-depth method development.
Advanced HW Series (HW723/HW723PC): Color touchscreen, ultra-narrow 1.7 nm bandwidth for higher resolution. HW723PC features a proportional double-beam system and 8-cell automatic sample holder, ideal for high-throughput and regulated laboratory testing.
Entry–Level (721/722/722S/7230G): Manual wavelength adjustment, suitable for teaching experiments and basic routine QC. 7230G includes a standard dedicated printer for direct data documentation.
Mid–Range Automatic (723/723PC): Automatic wavelength positioning with higher accuracy; 723PC adds PC software, spectral scanning and kinetic testing functions for in-depth method development.
Advanced HW Series (HW723/HW723PC): Color touchscreen, ultra-narrow 1.7 nm bandwidth for higher resolution. HW723PC features a proportional double-beam system and 8-cell automatic sample holder, ideal for high-throughput and regulated laboratory testing.
| Cat# | Model | Wavelength Range | Bandwidth | Wavelength Accuracy | Stray Light | Printer | PC Software | Best For |
| 32091001 | 721 | 340-1000 nm | 4 nm | ±2 nm | ≤0.1%T | Optional | – | Teaching, basic QC |
| 32091002 | 721-100 | 340-1000 nm | 4 nm | ±2 nm | ≤0.1%T | Optional | – | Sugar industry, low-conc water |
| 32091003 | 722 | 330-1000 nm | 4 nm | ±2 nm | ≤0.1%T | Optional | – | Industrial QC, broader range |
| 32091004 | 722S | 325-1000 nm | 4 nm | ±2 nm | ≤0.1%T | Optional | – | Improved stability, lab use |
| 32091005 | 7230G | 320-1000 nm | 4 nm | ±2 nm | ≤0.1%T | Standard | Optional | Higher accuracy, documentation |
Standard accessories (721/722/7230G): 4 × 10 mm glass cuvettes, 10 mm cuvette holder, power cord, dust cover, manual, calibration certificate. 721-100 includes 100 mm glass cuvette and 10 cm holder instead of 10 mm set.
| Cat# | Model | Wavelength Range | Bandwidth | Wavelength Accuracy | Stray Light | Display | Scanning | PC Software | Optical System | Key Feature |
| 32091006 | 723 (Auto) | 320-1000 nm | 2 nm | ±1 nm | ≤0.05%T | LCD | No | Optional | Single-beam | Auto wavelength, ±1 nm accuracy |
| 32091007 | 723PC | 320-1000 nm | 2 nm | ±1 nm | ≤0.05%T | LCD | Yes | Included | Single-beam | Scanning + kinetics + PC software |
| 32091008 | HW723 | 320-1000 nm | 1.7 nm | ±0.5 nm | ≤0.05%T | Color touch | No | Optional | Single-beam | Touchscreen, narrow bandwidth |
| 32091009 | HW723PC | 320-1000 nm | 1.7 nm | ±0.5 nm | ≤0.05%T | Color touch | Yes | Included | Proportional double-beam | 8-cell holder, touchscreen, full software |
Standard accessories (all 723/HW723 models): 4 × 10 mm glass cuvettes, 2 × 10 mm quartz cuvettes, 10 mm cuvette holder, power cord, dust cover, manual, calibration certificate. HW723PC also includes automatic eight-cell sample holder.
| Parameter | 721/722/722S | 7230G | 723/723PC | HW723/HW723PC |
| Optical system | Single-beam | Single-beam | Single-beam | Single-beam / Proportional double-beam (HW723PC) |
| Wavelength range | 325-1000 nm (model dependent) | 320-1000 nm | 320-1000 nm | 320-1000 nm |
| Spectral bandwidth | 4 nm | 4 nm | 2 nm | 1.7 nm |
| Wavelength accuracy | ±2 nm | ±2 nm | ±1 nm | ±0.5 nm |
| Wavelength repeatability | 1 nm | 1 nm | 0.5 nm | 0.2 nm |
| Transmittance accuracy | ≤1%T | ≤0.5%T | ≤0.3%T | ≤0.3%T |
| Absorbance range | -0.301-3 A | -0.301-3 A | -0.4-4 A | -0.4-4 A |
| Stray light | ≤0.1%T | ≤0.1%T | ≤0.05%T | ≤0.05%T |
| Stability | ±0.002 A/h | ±0.001 A/h | ±0.001 A/h | ±0.001 A/h |
| Display | None or LCD | LCD | LCD | Color touchscreen |
| PC software | Optional | Optional | Standard on 723PC | Standard on HW723PC |
| Output interface | RS-232 (7230G) | RS-232 | RS-232 | USB, RS-232 |
Ordering notes: All models include factory calibration certificate. For custom dimensions, OEM branding, or bulk quotes, contact info@hawach.com.
Industry-wide colorimetric applications include:
A visible spectrophotometer measures only visible light (320-1000 nm) and is used for colored samples or colorimetric assays. A UV-Vis spectrophotometer also measures UV range (190-320 nm), enabling analysis of nucleic acids, proteins, and UV-active pharmaceuticals. Choose visible-only if your samples are inherently colored or can be derivatized to produce color.
721/722 – basic teaching/QC; 721-100 – sugar industry / trace water; 7230G – printer needed; 723 (Auto) – automated routine testing; 723PC – scanning & PC software required; HW723/HW723PC – research & regulated labs (HW723PC adds double-beam, 8-cell holder).
T.A.C.F. (Time-based Automatic Calibration Function) periodically recalibrates the instrument during long-term operation, maintaining measurement stability and accuracy over extended use sequences.
Yes. All Hawach visible spectrophotometers support 100 mm cuvettes with the optional extended holder. 721-100 includes it as standard. PC software (UV-Solution) is included on 723PC and HW723PC, optional on other models.
Proportional double-beam (HW723PC) measures sample and reference simultaneously, compensating for light source drift and environmental interference, providing superior long-term stability, higher precision, and reliable results for regulated pharmaceutical QC and high-throughput workflows.

The quality has a guarantee
Fast & safe shipping worldwide