+86-29-89284429

Hydrophobic PVDF Syringe Filters

Filter Media: Hydrophobic PVDF
Housing: Medical PP
Diameter: 4mm, 13mm, 25mm, 33mm, 50mm
Pore Size: 0.1μm, 0.22μm, 0.45μm, 0.65μm, 1.0μm, 3.0μm, 5.0μm

Availability: In Stock

Description

High-Performance Filtration for Organic Solvents, Gases & Low-Binding Applications

Hawach hydrophobic PVDF syringe filters are designed for organic solvent filtration, gas filtration, and low protein binding applications.

Built with polyvinylidene fluoride (PVDF) membrane, these filters provide:

  • Excellent chemical resistance
  • High flow rates
  • Ultra-low protein binding
  • Broad compatibility with solvents and biomolecules

They are widely used in HPLC sample preparation, pharmaceutical analysis, and gas/air filtration.

Recommended Choice (Most Popular Configuration)

Hydrophobic PVDF Syringe Filters (0.22 µm / 0.45 µm)

  • Hydrophobic membrane for solvent & gas filtration
  • Low protein binding -ideal for biomolecules
  • High chemical resistance (acids, bases, organic solvents)
  • Fast flow rate for efficient sample prep
  • Available in sterile and non-sterile formats

Best for organic solvents, volatile samples, and analytical workflows
Related filtration types: PTFE Syringe Filters (for strong solvents & gases), PES Syringe Filters (for aqueous & biological samples).

Instruction Drawing

syringe-filters-analysis-chart-800x281 (2)

Quick Selection Guide

ApplicationRecommended TypePore Size
HPLC / LC-MS solvent filtrationStandard PVDF0.22 µm
Gas / air filtrationHydrophobic PVDF0.22 µm
Protein / antibody samplesSterile PVDF0.22 µm
General solvent filtrationDisposable PVDF0.45 µm
Pre-filtrationDisposable PVDF0.65–1.0 µm

Product Series Overview

1. Disposable Hydrophobic PVDF Syringe Filters

Designed for routine solvent filtration and single-use workflows

  • Cost-effective solution
  • Strong chemical compatibility
  • High flow with dense pore distribution
  • Ideal for HPLC/GC sample prep and gas filtration

2. Standard Hydrophobic PVDF Syringe Filters

Designed for analytical and industrial applications

  • Broad solvent compatibility
  • High thermal and chemical stability
  • Suitable for acids, bases, and organic compounds
  • Compatible with HPLC, LC-MS, and environmental testing

3. Sterile PVDF Syringe Filters

Designed for pharmaceutical & biotech sterile filtration

  • Gamma sterilized (high sterility assurance)
  • Low extractables membrane
  • Consistent performance for sensitive samples
  • Ideal for biological and pharmaceutical workflows

Applications

Hydrophobic PVDF syringe filters are widely used in:

  • HPLC / LC-MS sample preparation
  • Organic solvent filtration
  • Gas and air filtration
  • Protein & antibody filtration
  • Pharmaceutical QC and sterile processing
  • Environmental and chemical analysis
  • Food and beverage testing

Why Choose PVDF Membrane?

PVDF is a fluoropolymer membrane known for its durability and chemical resistance.

Key advantages:

  • Hydrophobic → ideal for non-aqueous samples
  • Excellent chemical resistance (solvents, acids, bases)
  • Low protein binding → high recovery of biomolecules
  • High flow rate → faster filtration
  • Wide pH stability

PVDF is one of the most versatile membranes for both chemical and biological applications

Technical Specifications

ParameterSpecification
MembraneHydrophobic PVDF
Pore Sizes0.1 / 0.22 / 0.45 / 0.65 / 1.0 / 3.0 / 5.0 µm
Diameters4 / 13 / 25 / 33 / 50 mm
HousingMedical-grade polypropylene (PP)
Max Pressure~5.2–6.2 bar
TemperatureUp to 60°C
Flow RateHigh
Protein BindingLow

Ordering Information

Disposable PVDF Syringe Filters

SKUPore SizeDiameterUse Case
110621010.22 µm13 mmHPLC sample prep
110621020.45 µm13 mmSolvent filtration
110621030.22 µm25 mmRoutine lab use
110621040.45 µm25 mmGeneral filtration

Standard PVDF Syringe Filters

Below are the most commonly ordered configurations. For custom pore sizes, diameters, or OEM requirements, please contact us.

Cat#Pore SizeDiameter(mm)SterilePre-filterPackage(pcs/pk)
110641010.224NoNo100
110641020.454NoNo100
110681070.113NoNo100
110681030.2213NoNo100
110681040.4513NoNo100
110681080.125NoNo100
110681050.2225NoNo100
110681060.4525NoNo100
110681090.133NoNo50
110681210.2233NoNo50
110681220.4533NoNo50
110681100.150NoNo25
110681280.2250NoNo25
110681290.4550NoNo25
110685010.113NoPP100
110685020.2213NoPP100
110685030.4513NoPP100
110685090.125NoPP100
110685100.2225NoPP100
110685110.4525NoPP100
110685170.133NoPP50
110685180.2233NoPP50
110685190.4533NoPP50
110685330.113NoGF100
110685340.2213NoGF100
110685350.4513NoGF100
110685410.125NoGF100
110685420.2225NoGF100
110685430.4525NoGF100
110685490.133NoGF50
110685500.2233NoGF50
110685510.4533NoGF50

Sterile PVDF Syringe Filters

Below are the most commonly ordered configurations. For custom pore sizes, diameters, or OEM requirements, please contact us.

Cat#Pore Size(µm)Diameter(mm)SterilePackage(pcs/pk)
110643010.224Gamma sterile100
110643020.454Gamma sterile100
110683070.113Gamma sterile100
110683030.2213Gamma sterile100
110683040.4513Gamma sterile100
110683080.125Gamma sterile100
110683050.2225Gamma sterile100
110683060.4525Gamma sterile100
110683090.133Gamma sterile50
110683210.2233Gamma sterile50
110683220.4533Gamma sterile50
110683100.150Gamma sterile25
110683280.2250Gamma sterile25
110683290.4550Gamma sterile25

PVDF vs Other Membranes

MembraneBest UseLimitation
PVDFSolvents + biomoleculesNot ideal for strong ketones
PTFEStrong solvents, gasesRequires pre-wetting for water
PESAqueous & biologicalNot for organic solvents
NylonGeneral filtrationHigher protein binding

PVDF = Best balance between chemical resistance & low protein binding

Why Choose Hawach PVDF Syringe Filters?

  • ISO 9001 / ISO 13485 certified production
  • Cleanroom manufacturing for sterile series
  • Gamma sterilization (sterile products)
  • Low extractables & high consistency
  • OEM / private label available
  • Global bulk supply capability

Bulk Order & OEM Supply

  • Factory direct pricing
  • OEM branding & packaging
  • Bulk discounts for distributors
  • Fast global shipping
  • Technical support available

Request quotation within 24 hours

FAQ

What are PVDF syringe filters used for?

PVDF syringe filters are used for organic solvent filtration, gas filtration, and biological sample preparation, especially in HPLC and pharmaceutical analysis.

Are PVDF filters hydrophobic?

Yes. Hydrophobic PVDF filters repel water and are ideal for non-aqueous samples and gas filtration.

Can PVDF filters be used for proteins?

Yes. PVDF membranes have low protein binding, making them suitable for antibodies and enzymes.

What is the difference between PVDF and PTFE filters?

PVDF offers low protein binding and broader biological compatibility, while PTFE is mainly used for strong solvents and gases.

What pore size should I choose?

  • 0.22 µm → Fine filtration / sterile prep
  • 0.45 µm → General filtration
  • 1.0 µm → Pre-filtration
ISO9001 CE Certificates
The quality has a guarantee

The quality has a guarantee

Fast & safe shipping worldwide

Fast & safe shipping worldwide

Contact Hawach for a Quotation
Enter your email address and our sales staff will
contact you as soon as possible.

    Go to Top